| EM 300 DS, FOR ET 200 X, ELECTRO-MECH. DIRECT STARTER, SETTING RANGE 0.14...0.2A, AC-3, UP TO 0.06KW/400V, WITHOUT BRAKE CONTACT, W. 9-POLE MOTOR FEEDER AND 9-POLE POWER CONNECTION |
|
General details: |
Design of the product | | direct starter |
Product function / bus-communication | | Yes |
Protocol / will be supported / AS interface protocol | | No |
Protocol / will be supported / PROFIBUS DP protocol | | Yes |
Product component / outlet for enine brake | | No |
Item designation / according to DIN EN 61346-2 | | Q |
Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750 | | A |
Depth | mm | 134 |
Height | mm | 270 |
Width | mm | 140 |
|
Control circuit: |
type of voltage | | DC |
Control supply voltage | | |
- for DC / rated value / minimum
| V | 20.4 |
- for DC / rated value / maximum
| V | 28.8 |
|
Main circuit: |
Design of the short-circuit protection | | circuit-breakers |
Type of the motor protection | | bimetal |
Design of the switching contact | | electromechanical |
Operating voltage / rated value | | |
| V | 400 |
| V | 500 |
Service power | | |
- at AC-3 / at 400 V / rated value
| kW | 0.06 |
- for three-phase servomotors / at 400 V / at 50 Hz / for AC three-phase
| | |
| kW | 0.06 |
| kW | 0.06 |
Adjustable response current / of the current-dependent overload release | | |
| A | 0.14 |
| A | 0.2 |
Breaking capacity limit short-circuit current (lcu) / at 400 V / rated value | A | 50 |
|
Connection type: |
Design of the electrical connection / for main current circuit | | tab terminals |
|
Ambient conditions: |
Protection class IP | | IP65 |
Ambient temperature | | |
| °C | 0… 55 |
|
Certificates/approvals: | | |
General Product Approval | Shipping Approval | other | ROSTEST | | |
| |
|
last change: | Feb 6, 2012 |