DS1E-X FOR ET200S HIGH FEATURE DIRECT STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC CONTACTOR AC-3/TO 1.1KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROF

Артикул: 3RK1301-0AB10-0AB4
Производитель: Siemens


Наименование продукта
DS1E-X FOR ET200S HIGH FEATURE DIRECT STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC CONTACTOR AC-3/TO 1.1KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROFIENERGY CAPABLE ON PN
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2011-07-25
DS1E-X FOR ET200S HIGH FEATURE DIRECT STARTER SETTING RANGE 0.3...3A MECHANICAL SWITCHING ELECTRONIC CONTACTOR AC-3/TO 1.1KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROFIENERGY CAPABLE ON PN
 
General technical data:
product brand name   Sirius
product designation   motor starter ET 200S
Design of the product   direct starter
Product function    
  • bus-communication
  Yes
  • direct start
  Yes
  • reverse starting
  No
  • on-site operation
  Yes
  • short circuit protection
  Yes
Design of the switching contact   electromechanical
Product component / outlet for enine brake   Yes
Trip class   CLASS 5, 10, 15, 20
Type of assignement   2
Product equipment    
  • brake control with 230 V AC
  No
  • brake control with 24 V DC
  No
  • brake control with 180 V DC
  No
  • brake control with 500 V DC
  No
Product extension / braking module for brake control   Yes
Impulse voltage resistance / rated value kV 6
Insulation voltage / rated value V 500
Active power loss / typical W 9
Maximum permissible voltage for safe disconnection / between main circuit and auxiliary circuit V 400
Item designation    
  • according to DIN EN 61346-2
  Q
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  A
Type of mounting   Can be plugged into terminal module
Depth mm 150
Height mm 290
Width mm 65
 
Main circuit:
Operating voltage    
  • rated value
V 400 500
Adjustable response current    
  • of the current-dependent overload release
A 0.3 3
Service power    
  • at AC-3 / at 400 V / rated value
kW 1.1
  • for three-phase servomotors / at 400 V / at 50 Hz
   
  • for AC three-phase
kW 0.1 1.1
Breaking capacity limit short-circuit current (lcu) / at 400 V / rated value kA 50
Design of the short-circuit protection   circuit-breakers
Number of poles / for main current circuit   3
Type of the motor protection   solid-state
Mechanical operating cycles as operating time / of the main contacts / typical   100,000
 
Control circuit:
Type of voltage / of the controlled supply voltage   DC
Control supply voltage / 1    
  • for DC
V 24 24
Control supply voltage / 1 / for DC    
  • rated value
V 20.4 28.8
 
Supply voltage:
   
Type of voltage / of supply voltage   DC
Supply voltage / 1    
  • for DC
V 24 24
Supply voltage / 1 / for DC    
  • rated value
V 20.4 28.8
 
Ambient conditions:
Protection class IP   IP20
Ambient temperature    
  • during operating
°C 0 60
  • during storage
°C -40 +70
  • during transport
°C -40 +70
Relative humidity    
  • during operating phase
% 5 95
Resistance against vibration   2g
Resistance against shock   5g / 11 ms
Degree of pollution   3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131)
Installation altitude / at a height over sea level / maximum m 2,000
Built in orientation   vertical, horizontal
 
Communication:
   
Protocol / will be supported    
  • PROFIBUS DP protocol
  Yes
  • PROFINET protocol
  Yes
  • AS interface protocol
  No
Design of the interface / PROFINET protocol   Yes
Design of the electrical connection    
  • of the communication interface
  via backplane bus
  • for communication transmission
  via backplane bus
 
Connections:
   
Number of digital inputs   2
Number of sockets    
  • for digital input signals
  0
  • for digital output signals
  0
Product function    
  • digital inputs parameterizable
  Yes
  • digital outputs parameterizable
  No
Design of the electrical connection    