| RS1E-X FOR ET200S HIGH FEATURE REVERSING STARTER SETTING RANGE 2.4...16A MECHANICAL SWITCHING ELECTRONIC PROTECTION AC-3/TO 7.5KW/400V EXPANDABLE FOR BRAKE CONTROL MODULE 2DI MODULE 2DI MODULE MOTORSTARTER ES SIGNAL FROM CIRCUIT-BREAKER PARAMETERIZABLE DPV 1 CAPABLE PROFIENERGY CAPABLE ON PN |
|
General technical data: |
product brand name | | Sirius |
product designation | | motor starter ET 200S |
Design of the product | | reversing starter |
Product function | | |
| | Yes |
| | No |
| | Yes |
| | Yes |
| | Yes |
Design of the switching contact | | electromechanical |
Product component / outlet for enine brake | | Yes |
Trip class | | CLASS 5, 10, 15, 20 |
Type of assignement | | 2 |
Product equipment | | |
- brake control with 230 V AC
| | No |
- brake control with 24 V DC
| | No |
- brake control with 180 V DC
| | No |
- brake control with 500 V DC
| | No |
Product extension / braking module for brake control | | Yes |
Impulse voltage resistance / rated value | kV | 6 |
Insulation voltage / rated value | V | 500 |
Active power loss / typical | W | 11 |
Maximum permissible voltage for safe disconnection / between main circuit and auxiliary circuit | V | 400 |
Item designation | | |
- according to DIN EN 61346-2
| | Q |
- according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
| | A |
Type of mounting | | Can be plugged into terminal module |
Depth | mm | 150 |
Height | mm | 290 |
Width | mm | 130 |
|
Main circuit: |
Operating voltage | | |
| V | 400… 500 |
Adjustable response current | | |
- of the current-dependent overload release
| A | 2.4… 16 |
Service power | | |
- at AC-3 / at 400 V / rated value
| kW | 7.5 |
- for three-phase servomotors / at 400 V / at 50 Hz
| | |
| kW | 1.1… 7.5 |
Breaking capacity limit short-circuit current (lcu) / at 400 V / rated value | kA | 50 |
Design of the short-circuit protection | | circuit-breakers |
Number of poles / for main current circuit | | 3 |
Type of the motor protection | | solid-state |
Mechanical operating cycles as operating time / of the main contacts / typical | | 100,000 |
|
Control circuit: |
Type of voltage / of the controlled supply voltage | | DC |
Control supply voltage / 1 | | |
| V | 24… 24 |
Control supply voltage / 1 / for DC | | |
| V | 20.4… 28.8 |
|
Supply voltage: | | |
Type of voltage / of supply voltage | | DC |
Supply voltage / 1 | | |
| V | 24… 24 |
Supply voltage / 1 / for DC | | |
| V | 20.4… 28.8 |
|
Ambient conditions: |
Protection class IP | | IP20 |
Ambient temperature | | |
| °C | 0… 60 |
| °C | -40… +70 |
| °C | -40… +70 |
Relative humidity | | |
| % | 5… 95 |
Resistance against vibration | | 2g |
Resistance against shock | | 5g / 11 ms |
Degree of pollution | | 3 at 400 V, 2 at 500 V according to IEC60664 (IEC61131) |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Built in orientation | | vertical, horizontal |
|
Communication: | | |
Protocol / will be supported | | |
| | Yes |
| | Yes |
| | No |
Design of the interface / PROFINET protocol | | Yes |
Design of the electrical connection | | |
- of the communication interface
| | via backplane bus |
- for communication transmission
| | via backplane bus |
|
Connections: | | |
Number of digital inputs | | 2 |
Number of sockets | | |
- for digital input signals
| | 0 |
- for digital output signals
| | 0 |
Product function | | |
- digital inputs parameterizable
| | Yes |
- digital outputs parameterizable
| | No |
Design of the electrical connection |
|