| SIMATIC DP, ELECTRONIC BLOCK FOR ET 200L, DIGITAL, 16 DO 0,5A, 24V DC, EXPANDABLE WITH MAX. 16 CHANNELS W. TERM. BLOCK TB 16SC OF SMART CONNECT |
|
General information |
Vendor identification (VendorID) | 8028h |
Supply voltage |
Mains buffering |
Mains buffering, min. | 20 ms |
Load voltage L+ |
Rated value (DC) | 24 V |
Input current |
from load voltage L+ (without load), max. | 50 mA |
from supply voltage L+, max. | 180 mA |
Power losses |
Power loss, typ. | 4 W |
Hardware configuration |
Rack |
Required terminal block | TB 16L (expansion: digital and analog with SIMATIC SC) |
Digital outputs |
Number/binary outputs | 16 |
Functionality/short-circuit strength | Yes; Electronic |
Response threshold, typ. | 0.7 A |
Limitation of inductive shutdown voltage to | Typ. (L1+ or L2+ / L3+) -55 V |
Lamp load, max. | 5 W |
Controlling a digital input | Yes |
Load resistance range |
lower limit | 41 Ω |
upper limit | 28000 Ω |
Output voltage |
Rated value (DC) | 24 V |
for signal "1", min. | Ua - 3 V |
Output current |
for signal "1" rated value | 500 mA |
for signal "1" permissible range for 0 to 40 °C, min. | 1 mA |
for signal "1" permissible range for 0 to 40 °C, max. | 500 mA |
for signal "1" permissible range for 0 to 60 °C, max. | 0.5 A |
for signal "0" residual current, max. | 1 mA |
Output delay with resistive load |
0 to "1", max. | 50 ms |
1 to "0", max. | 200 ms |
Parallel switching of 2 outputs |
for increased power | No |
for redundant control of a load | Yes; only outputs of the same group |
Switching frequency |
with resistive load, max. | 100 Hz |
with inductive load, max. | 0.5 Hz |
on lamp load, max. | 8 Hz |
Aggregate current of outputs (per group) |
all mounting positions |
up to 60 °C, max. | 4 A |
Total current of the outputs (per module) |
horizontal installation |
up to 40 °C, max. | 3 A |
up to 60 °C, max. | 2 A |
all other mounting positions |
up to 40 °C, max. | 2 A |
Relay outputs |
Rated input voltage of relay coil L+ (DC) | 24 V |
Reverse polarity protection | Yes |
Cable length |
Cable length, shielded, max. | 1000 m |
Cable length unshielded, max. | 600 m |
Interfaces |
PROFIBUS DP |
Transmission rate, max. | 1.5 Mbit/s |
SYNC capability | Yes |
FREECE capability | Yes; for SC inputs |
Communication functions |
Bus protocol/transmission protocol | PROFIBUS DP |
Interrupts/diagnostics/status information |
Alarms |
Alarms | No |
Diagnostic messages |
Diagnostic functions | Yes |
Diagnostics indication LED |
Bus fault BF (red) | Yes |
Group error SF (red) | Yes |
Status indicator digital output (green) | Yes |
Monitoring 24 V voltage supply ON (green) | Yes |
Galvanic isolation |
Galvanic isolation digital outputs |
between the channels | No |
between the channels and PROFIBUS DP | Yes |
Isolation |
Isolation checked with | 500 V DC |
Dimensions |
Width | 145 mm |
Height | 60 mm |
Depth | 60.5 mm |
Weight |
Weight, approx. | 130 g |
Status | Mar 5, 2012 |