| SIMATIC DP, ELECT. SUBMODULE FOR ET 200ISP, 4 DO, DC 17,4V/27MA |
|
Input current |
from load voltage L+ (without load), max. | 300 mA |
Power losses |
Power loss, typ. | 2.1 W |
Digital outputs |
Number/binary outputs | 4 |
Functionality/short-circuit strength | Yes |
No-load voltage Uao (DC) | 17.4 V |
Internal resistor Ri | 150 Ω |
Trend key points E |
Voltage Ue (DC) | 13.2 V |
Current Ie | 27 mA; 54 mA when outputs connected in parallel |
Output delay with resistive load |
0 to "1", max. | 2 ms |
1 to "0", max. | 1.5 ms |
Parallel switching of 2 outputs |
for increased power | Yes |
Switching frequency |
with resistive load, max. | 100 Hz |
with inductive load, max. | 2 Hz |
Cable length |
Cable length, shielded, max. | 200 m |
Cable length unshielded, max. | 200 m |
Interrupts/diagnostics/status information |
Alarms |
Alarms | No |
Diagnostic alarm | Yes; Parameterizable |
Diagnostic messages |
Diagnostic information readable | Yes |
Wire break | Yes; R > 10 kohms, I < 100 µA |
Short circuit | Yes; R< 800 ohms (one output), R< 40 ohms (outputs connected in parallel) |
Diagnostics indication LED |
Group error SF (red) | Yes |
Status indicator digital output (green) | Yes; Per channel |
Galvanic isolation |
Galvanic isolation digital outputs |
between the channels | No |
between the channels and the backplane bus | Yes |
between the channels and the load voltage L+ | Yes |
Permissible potential difference |
between different circuits | 60 V DC/30 V AC |
Standards, approvals, certificates |
CE mark | Yes |
Use in hazardous areas |
Type of protection acc. to EN 50020 (CENELEC) | II2 G (1) GD EEx ib[ia] IIC T4 |
Type of protection acc. to KEMA | 04 ATEX 1249 |
Dimensions |
Width | 30 mm |
Height | 129 mm |
Depth | 136.5 mm |
Weight |
Weight, approx. | 255 g |
Status | Mar 12, 2012 |