Product name | SINUMERIK 840D powerline NCU 573.5 |
Device series | SINUMERIK 840D |
Processor | Pentium III |
Processor / clock frequency | 933000000 Hz |
Working memory (RAM) | 64 MB DRAM, 8 MB SRAM |
SIMATIC S7 - integrated | PLC 317-2 DP |
Dimension / width | 50 mm |
Dimension / height | 316 mm |
Dimension / depth | 207 mm |
Weight / approx. | 1.05 kg |
Input voltage | via SIMODRIVE device bus |
Power loss | 40 W |
Mounting position | vertical |
Cooling | Open-circuit ventilation |
Approval | CE, cULus |
| |
|
Degree of protection | IP20 (with NCU box) |
Degree of protection / front panel | IP20 |
Degree of protection / rear | IP00 |
Humidity class | Class 3K5 condensation and icing excluded. Low air temperature 0 °C (+32 °F) |
Relative air humidity / operation | < 95% for 1h, annual average < 65% |
Relative air humidity / storage | 10 ... 95% |
Relative air humidity / transport | 10 ... 95% |
Relative air humidity / test standard | DIN EN 60068-2-1, 60068-2-2, 60068-2-14, 60068-2-30 |
Ambient temperature / in operation / min. | 0 °C |
Ambient temperature / in operation / max. | 55 °C |
Ambient temperature / during storage / min. | -20 °C |
Ambient temperature / during storage / max. | 60 °C |
Ambient temperature / during transport / min. | -20 °C |
Ambient temperature / during transport / max. | 60 °C |
Temperature / temperature change / max. | 12 °C/h |
Temperature / temperature change / max. / operation | 10 °C/h |
Temperature / temperature change / max. / transport | 18 °C/h |
Ambient conditions / mechanical ambient conditions / vibration / operation | 10-58 Hz: 0,075 mm, 59-500 Hz: 9,8 m/s² |
Ambient conditions / mechanical ambient conditions / vibration / transport | 5-9 HZ: 3,5 mm, 9-200 Hz: 9,8 m/s² |
Ambient conditions / mechanical ambient conditions / vibration / test standard | DIN EN 60068-2-6 |
Ambient conditions / mechanical ambient conditions / shock strength / operation | 50 m/s², 30 ms, 18 shocks |
Ambient conditions / mechanical ambient conditions / shock strength / transport | 300 m/s², 6 ms, 18 shocks |
Ambient conditions / mechanical ambient conditions / shock strength / test standard | DIN EN 60068-2-27 |
| |
|
Interfaces | OPI/MPI/S7-300/PROFIBUS-DP/Drive bus/Device bus/2 probes/2 handwheels/4 inputs/outputs/Link module |
Interfaces / PC card slot | PCMCIA |
Interfaces / PROFIBUS-DP/MPI | MPI/DP RS 485 |
Interfaces / PROFIBUS-DP | 1,5Mbaud |
Interfaces / handwheel | 2 handwheels via cable distributor |
Interfaces / inputs / outputs | Via cable distributor |
| |
letzte Änderung: | Jan 19, 2012 |