| SIMATIC WINAC MP 2007 SOFTWARE SPS FOR MP377 PLATFORMS INCL. SINGLE LICENSE ON USB STICK INCL. ELECTRONIC DOCU |
|
Memory |
Work memory |
integrated | 512 kbyte |
expandable | No |
Load memory |
integrated RAM, max. | 1.2 Mbyte |
CPU-blocks |
DB |
Number, max. | 2048; FBs+FCs+DBs=2048 |
Size, max. | 64 kbyte |
FB |
Number, max. | 2048; FBs+FCs+DBs=2048 |
Size, max. | 64 kbyte |
FC |
Number, max. | 2048; * max. 2048 total |
Size, max. | 64 kbyte |
OB |
Number, max. | 18 |
Size, max. | 64 kbyte |
Number of free cycle OBs | 1 |
Number of time alarm OBs | 1 |
Number of delay alarm OBs | 1 |
Number of time interrupt OBs | 1 |
Number of process alarm OBs | 1 |
Number of startup OBs | 2 |
Number of asynchronous error OBs | 6 |
Nesting depth |
per priority class | 16 |
additional within an error OB | 2 |
Counters, timers and their retentivity |
S7 counter |
Number | 512 |
of which retentive without battery |
adjustable | Yes |
lower limit | 0 |
upper limit | 512 |
Retentivity |
adjustable | Yes |
preset | 8 |
Counting range |
lower limit | 0 |
upper limit | 999 |
IEC counter |
present | Yes; SFB0, SFB1, SFB2 |
S7 times |
Number | 512 |
of which retentive without battery |
adjustable | Yes |
lower limit | 0 |
upper limit | 512 |
Retentivity |
adjustable | Yes |
preset | 0 |
Time range |
lower limit | 10 ms |
upper limit | 9990 s |
IEC timer |
present | Yes; SFB3, SFB4, SFB5 |
Data areas and their retentivity |
retentive data area in total (incl. times, counters, flags), max. | 256 kbyte |
Flag |
Number, max. | 4 kbyte |
Retentivity available | Yes |
Data blocks |
Number, max. | 2048 |
Size, max. | 64 kbyte |
Local data |
per priority class, max. | 16384 byte; Max. for all priority classes |
Address area |
I/O address area |
Inputs | 8 kbyte |
Outputs | 8 kbyte |
of which, distributed |
Inputs | 8 kbyte |
Outputs | 8 kbyte |
Process image |
Inputs | 2 kbyte |
Outputs | 2 kbyte |
Inputs, adjustable | 2 kbyte |
Outputs, adjustable | 2 kbyte |
Inputs, default | 512 byte |
Outputs, default | 512 byte |
consistent data, max. | 32 byte |
Hardware configuration |
Number of DP masters |
integrated | 1 |
Time of day |
Operating hours counter |
Number | 8 |
Number/Number range | 0 to 7 |
1st interface |
DP master |
Number of connections, max. | 8 |
Services |
PG/OP communication | Yes |
Routing | Yes |
Global data communication | No |
S7 basic communication | No |
S7 communication | Yes |
Equidistance mode support | No |
SYNC/FREEZE | Yes |
Activation/deactivation of DP slaves | Yes |
DPV1 | Yes |
Transmission rate, max. | 12000 kbit/s |
Number of DP slaves, max. | 32 |
Address area |
Inputs, max. | 8.192 kbyte |
Outputs, max. | 8.192 kbyte |
User data per DP slave |
User data per DP slave, max. | 244 byte; Max. consistent user data length 32 bytes |
Communication functions |
PG/OP communication | Yes |
Routing | Yes |
Global data communication |
supported | No |
S7 basic communication |
supported | No |
S7 communication |
supported | Yes |
as server | Yes |
as client | Yes |
User data per job, max. | 0.48 kbyte |
Number of connections |
overall | 32; (DP max.8, rest PN) |
of which static | 30; DP max.6, rest PN |
usable for PG communication | |
reserved for PG communication | 1 |
usable for OP communication | |
reserved for OP communication | 1 |
usable for routing | 16 |
Number of logical connections (also in network), max. | 32 |