SIMATIC S7-400, CPU 414-3 768 KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.IF FOR IFM

Артикул: 6ES7414-3XJ00-0AB0
Производитель: Siemens


Наименование продукта
SIMATIC S7-400, CPU 414-3 768 KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.IF FOR IFM
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
1999-10-31 2005-01-01 2005-01-01 2015-01-01
    Версия от 2012-02-12
 
SIMATIC S7-400, CPU 414-3 768 KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.IF FOR IFM
CiR - Configuration in RUN
CiR synchronization time, basic load 100 ms
CiR synchronization time, time per I/O slave 120 µs
Supply voltage
24 V DC Yes
Input current
from backplane bus 5 V DC, typ. 1.5 A
from backplane bus 5 V DC, max. 1.6 A; typ. 1.5 A
from backplane bus 24 V DC, max. 450 mA; Total current consumption of the components connected to the MPI/DP interfaces, but no more than 150 mA per interface
Power losses
Power loss, typ. 7.5 W
Backup battery
Battery operation
Backup current, typ. 40 µA
Backup current, max. 420 µA
Feeding of external backup voltage to CPU 5 to 15 VDC
Memory
Data and program memory
Data memory, max. 384 kbyte
Program memory, max. 384 kbyte
Work memory
integrated 768 kbyte
expandable No
Load memory
expandable FEPROM Yes; with Memory Card (FLASH)
expandable FEPROM, max. 64 Mbyte
integrated RAM, max. 256 kbyte
expandable RAM Yes; with Memory Card (RAM)
expandable RAM, max. 64 Mbyte
Backup
present Yes
with battery Yes; all data
without battery No
CPU processing times
for bit operations, min. 0.1 µs
for word operations, min. 0.1 µs
for fixed point arithmetic, min. 0.1 µs
for floating point arithmetic, min. 0.6 µs
CPU-blocks
DB
Number, max. 4095; DB 0 reserved
Size, max. 64 kbyte
FB
Number, max. 2048
Size, max. 64 kbyte
FC
Number, max. 2048
Size, max. 64 kbyte
OB
Number, max. see instruction list
Size, max. 64 kbyte
Number of time alarm OBs 4
Number of delay alarm OBs 4
Number of time interrupt OBs 4
Number of process alarm OBs 4
Nesting depth
per priority class 24
additional within an error OB 2
Counters, timers and their retentivity
S7 counter
Number 256
Retentivity
adjustable Yes
lower limit 0
upper limit 255
preset Z 0 to Z 7
Counting range
lower limit 1
upper limit 999
IEC counter
present Yes
Type SFB
S7 times
Number 256
Retentivity
adjustable Yes
lower limit 0
upper limit 255
preset No retentivity
Time range
lower limit 10 ms
upper limit 9990 s
IEC timer
present Yes
Type SFB
Data areas and their retentivity
retentive data area, total Total working and load memory (with backup battery)
Flag
Number, max. 8 kbyte
Retentivity available Yes; MB 0 to MB 8191
Retentivity preset MB 0 to MB 15
Number of clock memories 8; 1 memory byte
Data blocks
Number, max. 4096; DB 0 reserved
Size, max. 64 kbyte
Address area
I/O address area
Inputs 8 kbyte
Outputs 8 kbyte
of which, distributed
MPI/DP interface, inputs 2 kbyte
MPI/DP interface, outputs 2 kbyte
DP interface, inputs 6 kbyte
DP interface, outputs 6 kbyte
Process image
Inputs, adjustable 8 kbyte; adjustable at the expense of the code area of the RAM
Outputs, adjustable 8 kbyte; adjustable at the expense of the code area of the RAM
Inputs, default 256 byte
Outputs, default 256 byte
consistent data, max. 244 byte
Access to consistent data in process image Yes
Subprocess images
Number of subprocess images, max. 8
Digital channels
Inputs 65536
Outputs 65536
Inputs, of which central 65536
Outputs, of which central 65536
Analog channels
Inputs 4096
Outputs 4096
Inputs, of which central