SCALANCE X104-2, UNMANAGED IE SWITCH, 4 X 10/100MBIT/S RJ45 PORTS, 2 X 100 MBIT/S MULTIMODE BFOC, LED DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON, REDUNDANT VOLTAGE SUPPLY, W. ELECTRONIC MANUALS ON CD

Артикул: 6GK5104-2BB00-2AA3
Производитель: Siemens


Наименование продукта
SCALANCE X104-2, UNMANAGED IE SWITCH, 4 X 10/100MBIT/S RJ45 PORTS, 2 X 100 MBIT/S MULTIMODE BFOC, LED DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON, REDUNDANT VOLTAGE SUPPLY, W. ELECTRONIC MANUALS ON CD
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2004-12-11
    Версия от 2012-02-19
 
Product-type designation SCALANCE X104-2
SCALANCE X104-2, UNMANAGED IE SWITCH, 4 X 10/100MBIT/S RJ45 PORTS, 2 X 100 MBIT/S MULTIMODE BFOC, LED DIAGNOSTICS, FAULT SIGNAL. CONTACT WITH SET BUTTON, REDUNDANT VOLTAGE SUPPLY, W. ELECTRONIC MANUALS ON CD
Transmission rate
Transfer rate / 1 10 Mbit/s
Transfer rate / 2 100 Mbit/s
Interfaces
Number of electrical/optical connections / for network components or terminal equipment / maximum 6
Number of electrical connections  
  • for network components and terminal equipment
4
  • for alarm contact
1
  • for power supply
1
  • for redundant power supply
1
Design of electrical connection  
  • for network components and terminal equipment
RJ45 port
  • for signaling contact
2-pole terminal block
  • for power supply
4-pole terminal block
Number of optical interfaces / for optical waveguide  
  • at 100 Mbit/s
2
Design of optical interface / for optical waveguide  
  • at 100 Mbit/s
BFOC sockets (multimode up to 5 km)
Connectable optical power relative to 1 mW  
  • of the transmitter output
-19 -14 dB
  • of the receiver input / maximum
-14 dB
Optical sensitivity relative to 1 mW / of the receiver input / minimum -32 dB
Attenuation / of fiber-optic cable transmission link / minimum necessary 0 dB
Range / at the optical interface / depending on the optical fiber used 0 5 km
Inputs/outputs  
Operating voltage / of signaling contacts / at DC / rated value 24 V
Operating current / of signaling contacts / at DC / maximum 0.1 A
Supply voltage, current consumption, power loss
Type of voltage / of supply voltage DC
Supply voltage / external 24 V
  • minimum
18 V
  • maximum
32 V
Product component / fusing at power supply input Yes
Consumed current / maximum 0.16 A
Active power loss / at 24 V / for DC 3.8 W
Permitted ambient conditions
Ambient temperature  
  • during operating
-10 +60 °C
  • during storage
-40 +80 °C
  • during transport
-40 +80 °C
Relative humidity  
  • at 25 °C / without condensation / during operating / maximum
95 %
Protection class IP IP30
Design, dimensions and weight
Design compact
Width 60 mm
Height 125 mm
Depth 124 mm
Net weight 0.78 kg
Type of mounting  
  • 35 mm DIN rail mounting
Yes
  • wall mounting
Yes
  • S7-300 rail mounting
Yes
Standards, specifications, approvals
Standard  
  • for EMC / from FM
FM3611: Class 1, Division 2, Group A, B, C, D / T.., Class 1, Zone 2, Group IIC, T..
  • for hazardous zone
EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA IIT.., KEMA 07 ATEX 0145 X
  • for safety / of CSA and UL
UL 60950-1, CSA C22.2 No. 60950-1
  • for hazardous area / of CSA and UL
UL 1604 and UL 2279-15 (Hazardous Location), Class 1 / Division 2 / Group A, B, C, D / T.., Class 1 / Zone 2 / Group IIC / T..
  • for emitted interference
EN 61000-6-4 (Class A)
  • for interference immunity
EN 61000-6-2
Verification of suitability EN 61000-6-2, EN 61000-6-4
  • CE mark
Yes
  • C-Tick
Yes
Marine classification association  
  • American Bureau of Shipping Europe Ltd. (ABS)
Yes
  • Bureau Veritas (BV)
Yes
  • Det Norske Veritas (DNV)
Yes
  • Germanische Lloyd (GL)
Yes
  • Lloyds Register of Shipping (LRS)
Yes
  • Nippon Kaiji Kyokai (NK)
Yes
  • Polski Rejestr Statkow (PRS)
Yes
 
letzte ?nderung:
Feb 15, 2012

Назад в раздел