LOAD FEEDER FUSELESS REVERSING DUTY, AC 400V, SZ S0, 11. . .16A, AC 230V SPRING-LOADED CONNECTION FOR BUSBAR SYSTEMS 60MM TYPE OF COORDINATION 2, IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NO+1NC (CONTACTOR)

Артикул: 3RA2220-4AH26-0AP0
Производитель: Siemens


Наименование продукта
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400V, SZ S0, 11. . .16A, AC 230V SPRING-LOADED CONNECTION FOR BUSBAR SYSTEMS 60MM TYPE OF COORDINATION 2, IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NO+1NC (CONTACTOR)
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2009-11-19
LOAD FEEDER FUSELESS REVERSING DUTY, AC 400V, SZ S0, 11. . .16A, AC 230V SPRING-LOADED CONNECTION FOR BUSBAR SYSTEMS 60MM TYPE OF COORDINATION 2, IQ = 150KA (ALSO FULFILLS TYPE OF COORDINATION 1) 1NO+1NC (CONTACTOR)
 
General technical data:
product brand name   SIRIUS
product designation   non-fused load feeders 3RA2
Design of the product   reversing starter
Size of the load feeder   S0
Protection class IP / on the front   IP20
Degree of pollution   3
Insulation voltage / rated value V 690
Installation altitude / at a height over sea level / maximum m 2,000
Ambient temperature    
  • during transport
°C -55 +80
  • during storage
°C -55 +80
  • during operating
°C -20 +60
Impulse voltage resistance / rated value kV 6
Active power loss / per conductor / typical W 4.3
Item designation    
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  Q
  • according to DIN EN 61346-2
  Q
Type of assignement   2
Mechanical operating cycles as operating time / of the contactor    
  • typical
  10,000,000
Manufacturer article number    
  • of the circuit-breakers included in the scope of supply
  3RV2021-4AA20
  • of the contactor included in the scope of supply
  3RT2026-2AP00
  • of the RS applied assembly kit
  8US1250-5AT10
  • of the link module included in the scope of supply
  3RA2921-2AA00
  • of the busbar adapter included in the scope of supply
  8US1251-5NT11
Design of the switching contact   mechanical
Type of the motor protection   bimetal
Adjustable response current    
  • of the current-dependent overload release
A 11 16
 
Communication:
Product function / bus-communication   No
Protocol / will be supported    
  • AS interface protocol
  No
  • PROFIBUS DP protocol
  No
  • PROFINET protocol
  No
Product extension / function module for communication   No
 
Main circuit:
Number of poles / for main current circuit   3
Number of NC contacts / for main contacts   0
Number of NO contacts / for main contacts   3
Operating voltage / at AC-3 / rated value / maximum V 690
Operating current    
  • at AC-1 / at 400 V / rated value
A 16
  • at AC-2 / at 400 V / rated value
A 15.5
  • at AC-3 / at 400 V / rated value
A 15.5
  • at AC-4 / at 400 V / rated value
A 15.5
Service power    
  • at AC-2 / at 400 V / rated value
W 7,500
  • at AC-3
   
  • at 400 V / rated value
W 7,500
  • at 500 V / rated value
W 7,500
  • at 690 V / rated value
W 11,000
  • at AC-4 / at 400 V / rated value
W 7,500
Off-load operating frequency 1/h 5,000
Frequency of operation    
  • at AC-1 / according to IEC 60947-6-2 / maximum
1/h 1,000
  • at AC-2 / according to IEC 60947-6-2 / maximum
1/h 1,000
  • at AC-3 / according to IEC 60947-6-2 / maximum
1/h 1,000
  • at AC-4 / according to IEC 60947-6-2 / maximum
1/h 300
 
Control circuit:
Type of voltage / of the controlled supply voltage   AC
Control supply voltage frequency    
  • 1 / rated value
Hz 50
Control supply voltage / 1    
  • at 50 Hz / for AC / rated value
V 230
  • at 60 Hz / for AC / rated value
V 230
Apparent holding power / of the solenoid / for AC V·A 9.8
Inductive power factor / with the pull-in power of the coil   0.27
 
Auxiliary circuit:
Product extension / auxiliary switch   Yes
Number of NC contacts / for auxiliary contacts   1
Number of NO contacts / for auxiliary contacts   1
Number of change-over switches / for auxiliary contacts   0
 
Inputs/ Outputs:
Number of digital inputs   0
 
Short-circuit:
Product function / short circuit protection   Yes
Design of the short-circuit protection   circuit-breakers
Breaking capacity limit short-circuit current (lcu)    
  • at 400 V / rated value
A 25,000
  • at 500 V / rated value
A 5,000
  • at 690 V / rated value
A 2,000
 
Installation/mounting/dimensions:
Built in orientation   vertical
Type of mounting   Назад в раздел