SEMI-COND. CONTACTOR 3RF2, 1-PH AC 51 10 A 40 DEGREES C 24-230 V / 110-230 V AC SPRING-LOADED TERMINAL

Артикул: 3RF2310-2AA22
Производитель: Siemens


Наименование продукта
SEMI-COND. CONTACTOR 3RF2, 1-PH AC 51 10 A 40 DEGREES C 24-230 V / 110-230 V AC SPRING-LOADED TERMINAL
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2003-07-15
SEMI-COND. CONTACTOR 3RF2, 1-PH AC 51 10 A 40 DEGREES C 24-230 V / 110-230 V AC SPRING-LOADED TERMINAL
 
General technical data:
product brand name   SIRIUS
product designation   solid-state contactor
Product function   zero-point switching
Number of poles / for main current circuit   1
Protection class IP   IP20
Ambient temperature    
  • during operating
°C -25 +60
  • during storage
°C -55 +80
Installation altitude / at a height over sea level / maximum m 1,000
Resistance against vibration / according to IEC 60068-2-6   2g
Resistance against shock / according to IEC 60068-2-27   15g / 11 ms
Item designation    
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  K
  • according to DIN EN 61346-2
  Q
Number of NC contacts / for auxiliary contacts   0
Number of NO contacts / for auxiliary contacts   0
Number of change-over switches / for auxiliary contacts   0
 
Main circuit:
Number of NO contacts / for main contacts   1
Number of NC contacts / for main contacts   0
Operating current    
  • at AC-1 / at 400 V / rated value
A 10.5
  • at AC-51 / rated value
A 10.5
Operating current / minimum mA 100
Operating voltage    
  • at 50 Hz / at AC / rated value
V 24 230
  • at 60 Hz / at AC / rated value
V 24 230
Working area related to the operating voltage    
  • at 50 Hz / for AC
V 20 253
  • at 60 Hz / for AC
V 20 253
Operating frequency    
  • rated value
Hz 50 60
Relative symmetrical tolerance / of the operation frequency % 10
Insulation voltage / rated value V 600
Voltage slew rate / at the thyristor / for main contacts / maximum permissible V/µs 500
Block voltage / at the thyristor / for main contacts / maximum permissible V 800
Reverse current / of the thyristor mA 10
Derating temperature °C 40
Active power loss / total / typical W 11
Resistance against the impulse current / rated value A 200
I2t-level / maximum A²·s 200
 
Control circuit:
Control supply voltage frequency    
  • 1 / rated value
Hz 50
  • 2 / rated value
Hz 60
Type of voltage / of the controlled supply voltage   AC
Control supply voltage / 1    
  • at 50 Hz / for AC
   
  • initial rated value
V 110
  • final rated value
V 230
  • at 60 Hz / for AC
   
  • initial rated value
V 110
  • final rated value
V 230
Control supply voltage    
  • at 50 Hz / for AC / final value for signal<0>-recognition
V 40
  • at 60 Hz / for AC / final value for signal<0>-recognition
V 40
Tolerance of the line frequency Hz 5
Relative symmetrical tolerance / of the supply voltage frequency % 10
Control current    
  • at minimum control supply voltage / for AC
mA 2
  • for AC / rated value
mA 15
Fuse assignments
 
https://www.automation.siemens.com/cd-static/material/info/3RF21_eng.pdf
 
Installation/mounting/dimensions:
Type of mounting   screw and snap-on mounting onto 35 mm standard mounting rail
Type of fixing/fixation / series installation   Yes
Design of the thread / of the screw for fastening of the operating resource   M4
Tightening torque / of the screw for fastening of the operating resource N·m 1.5
Width mm 22.5
Height mm 100
Depth mm 94
 
Connections:
Design of the electrical connection / for main current circuit   spring-loaded terminals
Type of the connectable conductor cross-section    
  • for main contacts
   
  • solid
  2x (0.5 ... 2.5 mm²)
  • finely stranded
   
  • with conductor end processing
  2x (0.5 ... 1.5 mm²)
  • without conductor final cutting
  2x (0.5 ... 2.5 mm²)
  • for AWG conductors
   
  • for main contacts
  2x (18 ... 14)
  • for auxiliary and control contacts
  1x (AWG 20 ... 12)
  • for auxiliary and control contacts
   
  • solid
  0.5 ... 1.5 mm²
  • finely stranded
   

Назад в раздел