SOLID-STATE CONTACT.3PHASE 3RF2 AC53 5.2A 40 DEG. C 48-600V / 110-230V AC 2-PHASE CONTROLLED INSTANT. SWITCHING, SCREW TERMINAL

Артикул: 3RF2405-1BB26
Производитель: Siemens


Наименование продукта
SOLID-STATE CONTACT.3PHASE 3RF2 AC53 5.2A 40 DEG. C 48-600V / 110-230V AC 2-PHASE CONTROLLED INSTANT. SWITCHING, SCREW TERMINAL
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2007-12-03 2010-09-15 2010-11-22 2010-11-23
    Версия от 2012-02-19
 
SOLID-STATE CONTACT.3PHASE 3RF2 AC53 5.2A 40 DEG. C 48-600V / 110-230V AC 2-PHASE CONTROLLED INSTANT. SWITCHING, SCREW TERMINAL
 
General technical data:
product brand name   SIRIUS
product designation   solid-state motor contactor
Product function   instantaneous switching
Number of poles / for main current circuit   3
Protection class IP   IP20
Ambient temperature    
  • during operating
°C -25 +60
  • during storage
°C -55 +80
Installation altitude / at a height over sea level / maximum m 1,000
Resistance against vibration / according to IEC 60068-2-6   2g
Resistance against shock / according to IEC 60068-2-27   15g / 11 ms
Item designation    
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  K
  • according to DIN EN 61346-2
  Q
Number of NC contacts / for auxiliary contacts   0
Number of NO contacts / for auxiliary contacts   0
Number of change-over switches / for auxiliary contacts   0
 
Main circuit:
Number of NO contacts / for main contacts   2
Number of NC contacts / for main contacts   0
Operating current / at AC-3 / at 400 V / rated value A 5.2
Reverse current / of the thyristor mA 10
Derating temperature °C 40
Operating current / minimum mA 500
Resistance against the impulse current / rated value A 600
I2t-level / maximum A?·s 1,800
Service power / at AC-3 / at 400 V / rated value kW 2.2
Operating voltage    
  • at 50 Hz / at AC / rated value
V 48 600
  • at 60 Hz / at AC / rated value
V 48 600
Working area related to the operating voltage    
  • at 50 Hz / for AC
V 40 660
  • at 60 Hz / for AC
V 40 660
Operating frequency    
  • rated value
Hz 50 60
Relative symmetrical tolerance / of the operation frequency % 10
Insulation voltage / rated value V 600
Voltage slew rate / at the thyristor / for main contacts / maximum permissible V/µs 1,000
Block voltage / at the thyristor / for main contacts / maximum permissible V 1,600
Fuse assignments
 
https://www.automation.siemens.com/cd-static/material/info/3RF24_eng.pdf
 
Control circuit:
Type of voltage / of the controlled supply voltage   AC
Control supply voltage / 1    
  • at 50 Hz
   
  • for AC
V 90 253
  • at 60 Hz
   
  • for AC
V 90 253
Control supply voltage frequency    
  • 1
Hz 45
  • 2
Hz 66
Control supply voltage / at 50 Hz / for AC / final value for signal<0>-recognition V 90
Control supply voltage / at 60 Hz / for AC / final value for signal<0>-recognition V 90
Tolerance of the line frequency Hz 5
Relative symmetrical tolerance / of the supply voltage frequency % 10
Control current    
  • at minimum control supply voltage / for AC
mA 2
 
Installation/mounting/dimensions:
Type of mounting   screw and snap-on mounting onto 35 mm standard mounting rail
Type of fixing/fixation / series installation   Yes
Design of the thread / of the screw for fastening of the operating resource   M4
Tightening torque / of the screw for fastening of the operating resource N·m 1.5
Width mm 45
Height mm 95
Depth mm 100.8
 
Connections:
Design of the electrical connection / for main current circuit   screw-type terminals
Design of the thread / of the connection screw / for main contacts   M4
Tightening torque / for main contacts    
  • with screw-type terminals
N·m 2 2.5
Tightening torque (lbf·in) / for main contacts    
  • with screw-type terminals
lbf·in 18 22
Type of the connectable conductor cross-section    
  • for main contacts
   
  • solid
  2x (0.5 ... 2.5 mm?)
  • finely stranded
   
  • with conductor end processing
  2x (0.5 ... 1.5 mm?)
  • for AWG conductors
   
  • for main contacts
  2x (18 ... 14)
  • for auxiliary and control contacts
  1x (AWG 20 ... 12)
  • for auxiliary and control contacts
   
  • solid
  1x (0.5 ... 2.5 mm?), 2x (0.5 ... 1.0 mm?)
  • finely stranded
   
  • with conductor end processing
  1x (0.5 ... 2.5 mm?), 2x (0.5 ... 1.0 mm?)
  • without conductor final cutting
  1x (0.5 ... 2.5 mm?), 2x (0.5 ... 1.0 mm?)
Conductor cross section that can be connected &nb