General technical data:
product brand name   SIPLUS ECC1000
product designation   CM-100
charging current / maximum A 13
Product description   Actuation and monitoring of power components in the charging station, used for communication with the electric vehicle in acc. with IEC61851
Protection class IP / on the front   IP20
Degree of pollution   3, to IEC/EN 61010-1
Insulation voltage / with degree of pollution 3 / rated value V 230
 
Supply voltage:
   
Type of voltage / of supply voltage   AC
Supply voltage    
  • at 50 Hz
   
  • rated value
V 230
  • for AC / rated value
V 184 264
  • at 60 Hz
   
  • rated value
V 110
  • for AC / rated value
V 88 126
Symmetrical line frequency tolerance    
  • at 50 Hz
Hz 47.5 52.5
  • at 60 Hz
Hz 57 63
Consumed current / for rated value of supply voltage mA 100
 
Communication:
   
Product function / bus-communication   No
Protocol / is supported    
  • communication to electric vehicle according to IEC 61851
  Yes
  • Ethernet protocol
  No
  • EIB/KNX protocol
  No
 
Display:
   
Number of LEDs   1
Type of display    
  • for normal operation
  green, flashing / continuously illuminated, waiting for EF / charging active
  • as status display of the inputs
  orange, flashing (1 Hz), device waiting for enable
  • for fault signal
  red, flashing / twinkling, fault
 
Inputs/ Outputs:
Number of interfaces / to IEC 61851   1
Number of digital inputs   2
Type of voltage / of the input voltage   DC
Input voltage V 0 5
Number of digital outputs   0
 
Auxiliary circuit:
   
Number of NO contacts / for auxiliary contacts   4
Operating current / of auxiliary contacts    
  • at 230 V / AC
A 0.75
  • at 110 V / AC
A 0.75
  • at 24 V / DC
A 1
 
Klemmen:
   
Contact assignment    
  • of the bushing 1 at the PIN 1
  L: 110/230 V AC connection
  • of the bushing 1 at the PIN 2
 
N: 110/230 V AC connection
  • of the bushing 2 at the PIN 1
 
FE: Functional ground (part of the vehicle interface, connection to plug in accordance with IEC61851)
  • of the bushing 2 at the PIN 2
 
PX: Proximity (part of the vehicle interface, connection to plug in accordance with IEC61851)
  • of the bushing 2 at the PIN 3
  CP: Control Pilot (part of the vehicle interface, connection to plug in accordance with IEC61851)
  • of the bushing 3 at the PIN 1
 
AV: Auxilary voltage (readback voltage for device's own digital inputs)
  • of the bushing 3 at the PIN 2
 
EN: Enable (digital input for module enable)
  • of the bushing 3 at the PIN 3
 
HL: Hatch lock (digital input for status of connector lock)
  • of the bushing 4 at the PIN 1
 
P1: "Power" relay contact for switching load contactor
  • of the bushing 4 at the PIN 2
 
P2: "Power" relay contact for switching load contactor
  • of the bushing 4 at the PIN 3
 
V1: Ventilation relay contact for switching fan
  • of the bushing 4 at the PIN 4
  V2: Ventilation relay contact for switching fan
  • of the bushing 4 at the PIN 5
  H1: Hatch relay contact for switching locking
  • of the bushing 4 at the PIN 6
  H2: Hatch relay contact for switching locking
  • of the bushing 4 at the PIN 7
  S1: signal relay contact for reporting faults
  • of the bushing 4 at the PIN 8
  S2: signal relay contact for reporting faults
 
Ambient conditions:
   
Installation altitude / at a height over sea level / maximum m 2,000
Ambient temperature    
  • during storage
°C -25 +70
  • during operating
°C -25 +60
  • during transport
°C -25 +70
Relative humidity    
  • during operating phase
% 0 95
 
Electromagnetic compatibility:
   
EMC emitted interference / according to IEC 61000-6-3   Suitable for operation in residential, public and industrial environments
EMC immunity to interference / according to IEC 61000-6-2   Suitable for operation in industrial and residential environments
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4   4 kV / 5 kHz AC supply lines and functional ground, 2 kV / 5 kHz control lines and relay outputs
Conductor-bound parasitic coupling SURGE / according to IEC 61000-4-5   Назад в раздел