CHARGING CONTROLLER 16A FOR CHARGING UNTIS IEC 61851, MODE 3 230/400V POWER SUPPLY 24V DC

Артикул: 5TT3200-2KK30
Производитель: Siemens


Наименование продукта
CHARGING CONTROLLER 16A FOR CHARGING UNTIS IEC 61851, MODE 3 230/400V POWER SUPPLY 24V DC
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2011-05-31
 
 
General technical data:
product brand name   SIPLUS ECC1000
product designation   CM-100
charging current / maximum A 16
Product description   Actuation and monitoring of power components in the charging station, used for communication with the electric vehicle in acc. with IEC61851
Protection class IP / on the front   IP20
Degree of pollution   3, to IEC/EN 61010-1
Insulation voltage / with degree of pollution 3 / rated value V 230
 
Supply voltage:
   
Type of voltage / of supply voltage   DC
Supply voltage    
  • for DC / rated value
V 24
  • at DC
V 18 28
Consumed current / for rated value of supply voltage mA 300
 
Communication:
   
Product function / bus-communication   No
Protocol / is supported    
  • communication to electric vehicle according to IEC 61851
  Yes
  • Ethernet protocol
  No
  • EIB/KNX protocol
  No
 
Display:
   
Number of LEDs   1
Type of display    
  • for normal operation
  green, flashing / continuously illuminated, waiting for EF / charging active
  • as status display of the inputs
  orange, flashing (1 Hz), device waiting for enable
  • for fault signal
  red, flashing / twinkling, fault
 
Inputs/ Outputs:
Number of interfaces / to IEC 61851   1
Number of digital inputs   2
Type of voltage / of the input voltage   DC
Input voltage V 0 5
Number of digital outputs   0
 
Auxiliary circuit:
   
Number of NO contacts / for auxiliary contacts   4
Operating current / of auxiliary contacts    
  • at 230 V / AC
A 0.75
  • at 110 V / AC
A 0.75
  • at 24 V / DC
A 1
 
Klemmen:
   
Contact assignment    
  • of the bushing 1 at the PIN 1
  I+24 V: 24 V DC connection (SELV)
  • of the bushing 1 at the PIN 2
 
M: 24 V DC connection (SELV)
  • of the bushing 2 at the PIN 1
 
FE: Functional ground (part of the vehicle interface, connection to plug in accordance with IEC61851)
  • of the bushing 2 at the PIN 2
 
PX: Proximity (part of the vehicle interface, connection to plug in accordance with IEC61851)
  • of the bushing 2 at the PIN 3
  CP: Control Pilot (part of the vehicle interface, connection to plug in accordance with IEC61851)
  • of the bushing 3 at the PIN 1
 
AV: Auxilary voltage (readback voltage for device's own digital inputs)
  • of the bushing 3 at the PIN 2
 
EN: Enable (digital input for module enable)
  • of the bushing 3 at the PIN 3
 
HL: Hatch lock (digital input for status of connector lock)
  • of the bushing 4 at the PIN 1
 
P1: "Power" relay contact for switching load contactor
  • of the bushing 4 at the PIN 2
 
P2: "Power" relay contact for switching load contactor
  • of the bushing 4 at the PIN 3
 
V1: Ventilation relay contact for switching fan
  • of the bushing 4 at the PIN 4
  V2: Ventilation relay contact for switching fan
  • of the bushing 4 at the PIN 5
  H1: Hatch relay contact for switching locking
  • of the bushing 4 at the PIN 6
  H2: Hatch relay contact for switching locking
  • of the bushing 4 at the PIN 7
  S1: signal relay contact for reporting faults
  • of the bushing 4 at the PIN 8
  S2: signal relay contact for reporting faults
 
Ambient conditions:
   
Installation altitude / at a height over sea level / maximum m 2,000
Ambient temperature    
  • during storage
°C -25 +70
  • during operating
°C -25 +60
  • during transport
°C -25 +70
Relative humidity    
  • during operating phase
% 0 95
 
Electromagnetic compatibility:
   
EMC emitted interference / according to IEC 61000-6-3   Suitable for operation in residential, public and industrial environments
EMC immunity to interference / according to IEC 61000-6-2   Suitable for operation in industrial and residential environments
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4   2 kV / 5 kHz DC supply lines, 2 kV / 5 kHz control lines and relay outputs
Conductor-bound parasitic coupling SURGE / according to IEC 61000-4-5   Asymmetrical: DC supply lines 0.5 kV / 12 ohms; DC supply lines 1 kV / 42 ohms; control lines and functional ground 2 kV / 42 ohms; relay outputs 4kV / 12 ohms; evaluation criterion B. symmetrical: DC supply lines 0.5 kV / 2 ohms; DC
Field-bound parasitic coupling / according to IEC 61000-4-3   80 MHz to 1 GHz 10 V/m, 1.4 GHz to 2 GHz 3 V/m, 2 GHz to 2.7 GHz 1 V/m, evaluation criterion A
Electrostatic discharge / according to IEC 61000-4-2   4 kV contact discharge / 8 kV air discharge, evaluation criterion B
Resistance against shock / according to IEC 60068-2-27   15g / 11 ms / 3 shocks per axis
Shock resistance / during transport / to IEC 60068-2-29   1000 shocks / axis, 25g, 6 ms semi-sinusoidal
Vibration resistance    
  • during transport / to IEC 60068-2-6
  Назад в раздел