| POWER MODULE LA716I HP F0R HEATING SYSTEM CONTROL SIPLUS HCS716I. WITH 8 CHANNELS EACH MAX. 2300W. FOR USE A MODULES SUBRACK IS REQUIRED. THE 5 X 20 MM FUSES 10 AMP. QUICK-RESPONSE F.EACH CHANNEL ARE PLUGGED ON OPEN FUSE HOLDERS AND ARE EXCHANGEABLE. 2-PHASE POWER SUPPLY VIA FRONT SIDE 3-POLE TERMINALS (IN THE SCOPE OF SUPPLY). HEATER OUTLETS VIA 2 X 8-PIN CONNECTORS (NOT IN THE SCOPE OF SUPPLY). |
Product brand name | | SIPLUS |
|
Inputs/ Outputs: | | |
Number of outputs | | 8 |
Design of the electrical isolation | | Optocoupler |
Galvanic isolation / between the outputs | | No |
Output current / rated value | A | 10 |
Power capacity | | |
| W | 2,300 |
- of module / for star connection / at 40 °C
| | |
- with fan / per output / maximum
| kW | 14.72 |
- without fan / per output / maximum
| kW | 6.5 |
Type of load | | Ohmic load |
Design of short-circuit protection / per output | | Fuse 10 A |
|
Supply voltage: | | |
Type of voltage / of supply voltage | | AC |
Supply voltage / for AC / rated value | V | 230 |
Relative negative tolerance / of supply voltage | % | 18 |
Relative positive tolerance / of supply voltage | % | 15 |
Supply voltage frequency | | |
| Hz | 50… 60 |
Relative symmetrical tolerance / of the supply voltage frequency | % | 5 |
|
General technical data: | | |
Product function / temperature surveillance | | Yes |
Diagnose function | | Voltage diagnostics |
| | Yes |
| | Yes |
| | Yes |
| | Yes |
|
Communication: | | |
Design of the interface | | system interface |
|
Ambient conditions: | | |
Protection class IP | | IP00 |
Resistance against shock / according to IEC 60068-2-27 | | 15g / 11 ms / 3 shocks / axis |
Resistance against vibration / according to IEC 60068-2-6 | | 10 ... 58 Hz: 0.075 mm, 58 ... 500 Hz: 1g |
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV voltage supply cables / 2 kV signal cables |
Conductor-bound parasitic coupling SURGE / according to IEC 61000-4-5 | | on supply lines: 1 kV symmetrical, 2 kV asymmetrical, PROFIBUS line asymmetrical 1KV |
Conducted interference as high-frequency radiation / according to IEC 61000-4-6 | | 10 V (0.15 ... 80 MHz) |
Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV |
Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
Electrostatic discharge / according to IEC 61000-4-2 | | 4 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m (80 MHz ... 1000 MHz) |
EMC emitted interference | | Limit value class A to EN 55011 group 1 |
Installation altitude / at a height over sea level / maximum | m | 1,500 |
Ambient temperature | | |
| °C | -40… 70 |
| °C | 0… 55 |
| °C | -40… 70 |
Air pressure | | |
| hPa | 860… 1,080 |
| hPa | 660… 1,080 |
|
Connections: | | |
|
Stecker/Buchsen/Klemmen: | | |
Design of electrical connection / of outputs | | Socket strip 8-pin |
Type of connectable conductor cross sections | | |
- at the outputs / for AWG cables
| | 28 ... 16 |
Design of electrical connection / for supply voltage | | Connector, 3-pin |
Type of connectable conductor cross sections / for AWG cables / for supply voltage | | 24 ... 8 |
|
Installation/mounting/dimensions: | | |
Width | mm | 31 |
Height | mm | 233.4 |
Depth | mm | 279 |
|
Certificates/approvals: | | |
Verification of suitability | | CE |
|
|
Further information: |
Information- and Downloadcenter (Catalogs, Brochures,…) http://www.automation.siemens.com/mcms/topics/en/siplus/industrial-heating-control/Pages/home.aspx |
Industry Mall (Online ordering system) http://www.siemens.com/industrial-controls/mall |
Cax online generator: http://www.siemens.com/cax |
Service&Support (Manuals, Certificates, Characteristics, FAQs,...) http://support.automation.siemens.com/WW/view/en/6BK1700-4CA00-0AA0/all |
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=6BK1700-4CA00-0AA0 |
|
|
| |
|
last change: | Aug 25, 2011 |