2NO+2NC CONTACTOR, AC3: 7.5KW AC 230V 50HZ 4-POLE, 2NO+2NC, SZ: S00, SPRING-LOADED TERMINAL

Артикул: 3RT2518-2AP00
Производитель: Siemens


Наименование продукта
2NO+2NC CONTACTOR, AC3: 7.5KW AC 230V 50HZ 4-POLE, 2NO+2NC, SZ: S00, SPRING-LOADED TERMINAL
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2010-02-04
2NO+2NC CONTACTOR, AC3: 7.5KW AC 230V 50HZ 4-POLE, 2NO+2NC, SZ: S00, SPRING-LOADED TERMINAL
 
General technical data:
product brand name   SIRIUS
Size of the contactor   S00
Product extension / auxiliary switch   Yes
Protection class IP / on the front   IP20
Protection against electrical shock   finger-safe
Degree of pollution   3
Installation altitude / at a height over sea level / maximum m 2,000
Ambient temperature / during storage °C -55 +80
Ambient temperature / during operating °C -25 +60
Shock resistance    
  • at rectangular impulse
   
  • at AC
  7,3g / 5 ms, 4,7g / 10 ms
  • at sine pulse
   
  • at AC
  11,4g / 5 ms, 7,3g / 10 ms
Impulse voltage resistance / rated value kV 6
Insulation voltage / rated value V 690
Mechanical operating cycles as operating time    
  • of the contactor / typical
  30,000,000
  • of the contactor with added auxiliary switch block / typical
  10,000,000
  • of the contactor with added electronics-compatible auxiliary switch block / typical
  5,000,000
 
Main circuit:
Number of NC contacts / for main contacts   2
Number of NO contacts / for main contacts   2
Operating current    
  • at AC-1 / at 400 V
   
  • at 40 °C ambient temperature / rated value
A 22
  • at 60 °C ambient temperature / rated value
A 20
  • at AC-2 / at 400 V / rated value
A 16
  • at AC-3 / at 400 V / rated value
A 16
  • at AC-4 / at 400 V / rated value
A 11.5
Operating current    
  • with 1 current path / at DC-1
   
  • at 24 V / rated value
A 20
  • at 110 V / rated value
A 2.1
  • with 2 current paths in series / at DC-1
   
  • at 24 V / rated value
A 20
  • at 110 V / rated value
A 12
  • with 1 current path / at DC-3 / at DC-5
   
  • at 24 V / rated value
A 20
  • at 110 V / rated value
A 0.1
  • with 2 current paths in series / at DC-3 / at DC-5
   
  • at 24 V / rated value
A 20
  • at 110 V / rated value
A 0.35
Service power    
  • at AC-2 / at 400 V / rated value
kW 7.5
  • at AC-3 / at 400 V / rated value
kW 7.5
  • at AC-4 / at 400 V / rated value
kW 5.5
Active power loss / per conductor / typical W 2.2
Off-load operating frequency    
  • at AC
1/h 10,000
  • at DC
1/h 10,000
Frequency of operation / at AC-1 / according to IEC 60947-6-2 1/h 1,000
Frequency of operation / at AC-2 / according to IEC 60947-6-2 1/h 750
Frequency of operation / at AC-3 / according to IEC 60947-6-2 1/h 750
Frequency of operation / at AC-4 / according to IEC 60947-6-2 1/h 250
 
Control circuit:
Type of voltage / of the controlled supply voltage   AC
Control supply voltage / 1    
  • at 50 Hz / for AC / rated value
V 230
  • at 60 Hz / for AC / rated value
V 230
operating range factor control supply voltage rated value / of the magnet coil    
  • at 50 Hz / for AC
  0.8 1.1
  • at 60 Hz / for AC
  0.85 1.1
Apparent pull-in power / of the solenoid / for AC V·A 37
Apparent holding power / of the solenoid / for AC V·A 5.7
Inductive power factor    
  • with the pull-in power of the coil
  0.8
  • with the pull-in power of the coil
  0.25
Closing delay    
  • at AC
ms 8 33
Opening delay    
  • at AC
ms 4 15
Arcing time ms 10 15
 
Auxiliary circuit:
Contact reliability / of the auxiliary contacts   1 faulty switching per 100 million (17 V, 1 mA)
Number of NC contacts / for auxiliary contacts / instantaneous switching   0
Number of NO contacts / for auxiliary contacts / instantaneous switching   0
Operating current / of the auxiliary contacts    
  • at AC-12 / maximum
A 10
  • at AC-15
   
  • at 230 V
A 6
  • at 400 V
A 3
  • at DC-12
   
  • at 48 V