2NO+2NC CONTACTOR, AC3: 11KW AC 110V 50HZ 4-POLE, 2NO+2NC, SZ: S0, SCREW TERMINAL 1NO+1NC INTEGR.

Артикул: 3RT2526-1AF00
Производитель: Siemens


Наименование продукта
2NO+2NC CONTACTOR, AC3: 11KW AC 110V 50HZ 4-POLE, 2NO+2NC, SZ: S0, SCREW TERMINAL 1NO+1NC INTEGR.
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2010-05-01
2NO+2NC CONTACTOR, AC3: 11KW AC 110V 50HZ 4-POLE, 2NO+2NC, SZ: S0, SCREW TERMINAL 1NO+1NC INTEGR.
 
General technical data:
product brand name   SIRIUS
Size of the contactor   S0
Product extension / auxiliary switch   Yes
Protection class IP / on the front   IP20
Protection against electrical shock   finger-safe
Degree of pollution   3
Installation altitude / at a height over sea level / maximum m 2,000
Ambient temperature / during storage °C -55 +80
Ambient temperature / during operating °C -25 +60
Shock resistance    
  • at rectangular impulse
   
  • at AC
  8,3g / 5 ms, 5,3g / 10 ms
  • at sine pulse
   
  • at AC
  13,5g / 5 ms, 8,3g / 10 ms
Impulse voltage resistance / rated value kV 6
Insulation voltage / rated value V 690
Mechanical operating cycles as operating time    
  • of the contactor / typical
  10,000,000
  • of the contactor with added auxiliary switch block / typical
  10,000,000
  • of the contactor with added electronics-compatible auxiliary switch block / typical
  5,000,000
 
Main circuit:
Number of NC contacts / for main contacts   2
Number of NO contacts / for main contacts   2
Operating current    
  • at AC-1 / at 400 V
   
  • at 40 °C ambient temperature / rated value
A 40
  • at 60 °C ambient temperature / rated value
A 35
  • at AC-2 / at 400 V / rated value
A 25
  • at AC-3 / at 400 V / rated value
A 25
  • at AC-4 / at 400 V / rated value
A 15.5
Operating current    
  • with 1 current path / at DC-1
   
  • at 24 V / rated value
A 35
  • at 110 V / rated value
A 4.5
  • with 2 current paths in series / at DC-1
   
  • at 24 V / rated value
A 35
  • at 110 V / rated value
A 35
  • with 1 current path / at DC-3 / at DC-5
   
  • at 24 V / rated value
A 20
  • at 110 V / rated value
A 2.5
  • with 2 current paths in series / at DC-3 / at DC-5
   
  • at 24 V / rated value
A 35
  • at 110 V / rated value
A 15
Service power    
  • at AC-2 / at 400 V / rated value
kW 11
  • at AC-3 / at 400 V / rated value
kW 11
  • at AC-4 / at 400 V / rated value
kW 7.5
Active power loss / per conductor / typical W 1.6
Off-load operating frequency    
  • at AC
1/h 5,000
  • at DC
1/h 1,500
Frequency of operation / at AC-1 / according to IEC 60947-6-2 1/h 1,000
Frequency of operation / at AC-2 / according to IEC 60947-6-2 1/h 750
Frequency of operation / at AC-3 / according to IEC 60947-6-2 1/h 750
Frequency of operation / at AC-4 / according to IEC 60947-6-2 1/h 250
 
Control circuit:
Type of voltage / of the controlled supply voltage   AC
Control supply voltage / 1    
  • at 50 Hz / for AC / rated value
V 110
operating range factor control supply voltage rated value / of the magnet coil    
  • at 50 Hz / for AC
  0.8 1.1
  • at 60 Hz / for AC
  0.85 1.1
Apparent pull-in power / of the solenoid / for AC V·A 77
Apparent holding power / of the solenoid / for AC V·A 9.8
Inductive power factor    
  • with the pull-in power of the coil
  0.82
  • with the pull-in power of the coil
  0.25
Closing delay    
  • at AC
ms 8 40
Opening delay    
  • at AC
ms 4 16
Arcing time ms 10 10
 
Auxiliary circuit:
Contact reliability / of the auxiliary contacts   1 faulty switching per 100 million (17 V, 1 mA)
Number of NC contacts / for auxiliary contacts / instantaneous switching   1
Number of NO contacts / for auxiliary contacts / instantaneous switching   1
Operating current / of the auxiliary contacts    
  • at AC-12 / maximum
A 10
  • at AC-15
   
  • at 230 V
A 6
  • at 400 V
A 3
  • at DC-12
   
  • at 48 V
A 6
  • at 60 V
A