ACTUATOR-/INDICATOR COMPONENT CONTACT BLOCK, 30DEGR TILTED VL400,VL630,VL800,VL1250,VL1600 ALARM-/AUXILIARY SWITCH WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO Z= 150 UNITS PACKED

Артикул: 3SB3400-0J-ZX90
Производитель: Siemens


Наименование продукта
ACTUATOR-/INDICATOR COMPONENT CONTACT BLOCK, 30DEGR TILTED VL400,VL630,VL800,VL1250,VL1600 ALARM-/AUXILIARY SWITCH WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO Z= 150 UNITS PACKED
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2001-01-01
ACTUATOR-/INDICATOR COMPONENT CONTACT BLOCK, 30DEGR TILTED VL400,VL630,VL800,VL1250,VL1600 ALARM-/AUXILIARY SWITCH WITH 1 CONTACT ELEMENT SCREW TERMINAL, 1NO Z= 150 UNITS PACKED
 
General technical details:
product designation   contact block
Degree of pollution   class 3
Insulation voltage / rated value V 400
Impulse voltage resistance / rated value kV 4
Thermal current A 10
Contact reliability   one incorrect switching operation of 100 million switching operations (5 V, 1 mA)
Protection against electrical shock  
  • at AC-12 / at 24 V
A 10
  • at AC-12 / at 48 V
A 10
  • at AC-12 / at 110 V
A 10
  • at AC-12 / at 230 V
A 10
  • at AC-12 / at 400 V
A 10
  • at AC-15
   
  • at 24 V
A 6
  • at 48 V
A 6
  • at 110 V
A 6
  • at 230 V
A 6
  • at 400 V
A 3
  • at DC-12
   
  • at 24 V
A 10
  • at 48 V
A 5
  • at 110 V
A 2.5
  • at 230 V
A 1
  • at DC-13
   
  • at 24 V
A 3
  • at 48 V
A 1.5
  • at 110 V
A 0.7
  • at 230 V
A 0.3
Type of voltage    
  • of the operating voltage
  AC/DC
Operating voltage    
  • 1 / for DC / rated value
V 24
  • for DC
   
  • rated value
V 5 230
  • 1 / at 50 Hz / for AC / rated value
V 400
  • at 50 Hz / at AC
   
  • rated value
V 5 400
  • 1 / at 60 Hz / for AC / rated value
V 300
  • at 60 Hz / at AC
   
  • rated value
V 5 300
Number of NC contacts / for auxiliary contacts   0
Number of NO contacts / for auxiliary contacts   1
Number of change-over switches / for auxiliary contacts   0
Suitability for integration   front element
  • suspension pushbutton
  Yes
  • pressure selection button
  No
  • front element
  No
  • suspension switch
  Yes
Item designation    
  • according to DIN 40719 extendable after IEC 204-2 / according to IEC 750
  S
  • according to DIN EN 61346-2
  S
 
Mechanical design:
Design of the electrical connection   screw-type terminals
Tightening torque / for auxiliary contacts / with screw-type terminals N·m 0.8
Operating cycles / maximum 1/h 1,000
Electrical operating cycles as operating time / with contactors 3RT1015 to 3RT1026 / typical   100,000,000
Mechanical operating cycles as operating time / typical   10,000,000
protection class IP / of the housing   IP40
Type of mounting   front mounting
Product component    
  • fluorescent materials
  No
  • diode
  No
  • series resistance
  No
  • lamp transformer
  No
 
Connections:
   
Type of the connectable conductor cross-section    
  • for auxiliary contacts
   
  • solid
  2x (1 ... 1.5 mm²)
  • with conductor end processing
  2x (0.5 ... 0.75 mm²)
  • finely stranded
   
  • with conductor end processing
  2x (0.5 ... 1.5 mm²)
  • for AWG conductors / for auxiliary contacts
  2x (18 ... 14)
 
Ambient conditions:
Ambient temperature    
  • during operating
°C -25 +70
 
 
Further information:
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
http://www.siemens.com/industrial-controls/mall
CAx-Online-Generator
http://www.siemens.com/cax
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
http://support.automation.siemens.com/WW/view/en/3SB3400-0J-ZX90/all
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3SB3400-0J-ZX90
 
 
 
last change:
Mar 17, 2012

Назад в раздел