DIGITAL MONITORING RELAY VOLTAGE MONITORING, 22.5MM FOR IO-LINK 10 TO 600V AC/DC OVER- AND UNDERCURRENT HYSTERESIS 0.1 TO 300V ON DELAY TIME TRIPPING DELAY TIME 1 CHANGE-OVER CONTACT, SPRING-LOADED TERMINAL

Артикул: 3UG4832-2AA40
Производитель: Siemens


Наименование продукта
DIGITAL MONITORING RELAY VOLTAGE MONITORING, 22.5MM FOR IO-LINK 10 TO 600V AC/DC OVER- AND UNDERCURRENT HYSTERESIS 0.1 TO 300V ON DELAY TIME TRIPPING DELAY TIME 1 CHANGE-OVER CONTACT, SPRING-LOADED TERMINAL
Жизненный цикл продукта
3UG4832-2AA40">
3UG4832-2AA40"> Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
3UG4832-2AA40"> 2011-10-31
DIGITAL MONITORING RELAY VOLTAGE MONITORING, 22.5MM FOR IO-LINK 10 TO 600V AC/DC OVER- AND UNDERCURRENT HYSTERESIS 0.1 TO 300V ON DELAY TIME TRIPPING DELAY TIME 1 CHANGE-OVER CONTACT, SPRING-LOADED TERMINAL
Product function   Voltage monitoring relay
 
Measuring circuit:
   
Type of voltage / for monitoring   AC/DC
Number of poles / for main current circuit   1
Measurable line frequency Hz 40 500
Measurable voltage    
  • for AC
V 10 600
Adjustable voltage range V 10 600
Adjustable response delay time    
  • when starting
s 0 999.9
  • with lower or upper limit violation
s 0 999.9
Response time / maximum ms 450
Relative metering precision % 5
Precision of digital display   +/-1 digit
Relative temperature-related measurement deviation % 0.1
Relative repeat accuracy % 1
 
General technical details:
Design of the display   LCD
Product function    
  • tension window recognition of 1 phase
  Yes
  • tension window recognition of 3 phases
  No
  • tension window recognition DC
  Yes
  • overvoltage recognition of 1 phase
  Yes
  • overvoltage recognition of 3 phases
  No
  • overvoltage recognition DC
  Yes
  • undervoltage recognition of 1 phase
  Yes
  • undervoltage recognition of 3 phases
  No
  • undervoltage recognition DC
  Yes
  • reset external
  Yes
  • self-reset
  Yes
  • open-circuit or closed-circuit current principle
  Yes
Starting time / after the control supply voltage has been applied ms 1,000
Type of voltage / of the controlled supply voltage   DC
Control supply voltage    
  • for DC
   
  • rated value
V 18 30
Working range factor supply voltage rated value    
  • for DC
  0.75 1.25
Impulse voltage resistance / rated value kV 6
Recorded real power W 2
Protection class IP   IP20
Electromagnetic compatibility   IEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4
Resistance against vibration / according to IEC 60068-2-6   1 … 6 Hz: 15 mm, 6 … 500 Hz: 2g
Resistance against shock / according to IEC 60068-2-27   sinusoidal half-wave 15g / 11 ms
Installation altitude / at a height over sea level / maximum m 2,000
Maximum permissible voltage for safe disconnection    
  • between control and auxiliary circuit
V 690
  • between auxiliary circuit and auxiliary circuit
V 300
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4   2 kV
Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5   2 kV
Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5   1 kV
Electrostatic discharge / according to IEC 61000-4-2   6 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling / according to IEC 61000-4-3   10 V/m
Ambient temperature    
  • during operating
°C -25 +60
  • during storage
°C 85 -40
  • during transport
°C 85 -40
Design of the electrical isolation   Safe isolation
Galvanic isolation    
  • between entrance and outlet
  Yes
  • between the voltage supply and other circuits
  Yes
Mechanical operating cycles as operating time / typical   10,000,002
Electrical operating cycles as operating time / at AC-15 / at 230 V / typical   100,000
Operating cycles / with 3RT2 contactor / maximum 1/h 5,000
 
Communication:
   
Type of voltage supply / via input/ output link master   Yes
IO-Link transfer rate   COM2 (38,4 kBaud)
Protocol / will be supported / IO-Link protocol   Yes
Data volume    
  • of the address range of the outputs / with cyclical transfer
byte 2
  • of the address range of the inputs / with cyclical transfer
byte 4
Point-to-point cycle time / between master and IO-Link device / minimum ms 10
 
Mechanical design:
Width mm 22.5
Height mm 94
Depth mm 91
Built in orientation   any
Distance, to be maintained, to earthed part    
  • forwards
mm 0
  • backwards
mm 0
  • sidewards
mm 0
  • upwards
mm 0
    Назад в раздел