| ANALOG MONITORING RELAY PHASE SEQUENCE MONITORING 3X 160 TO 260V AC 50 TO 60 HZ 1 CHANGEOVER CONTACT SCREW TERMINAL REPLACEMENT PRODUCT FOR 3UG3511-1AQ50 OR 3UG3511-1AV50 |
Product function | | Phase monitoring relay |
|
Measuring circuit: | | |
Type of voltage / for monitoring | | AC |
Number of poles / for main current circuit | | 3 |
Measurable voltage | | |
| V | 160… 260 |
|
General technical details: |
Type of display / LED | | Yes |
Product function | | |
| | No |
| | No |
- phase sequence recognition
| | Yes |
- phase disturbance recognition
| | No |
| | No |
- overvoltage recognition of 3 phases
| | No |
- undervoltage recognition of 3 phases
| | No |
- tension window recognition of 3 phases
| | No |
| | Yes |
- open-circuit or closed-circuit current principle
| | No |
Starting time / after the control supply voltage has been applied | ms | 200 |
Response time / maximum | ms | 450 |
Type of voltage / of the controlled supply voltage | | AC |
Control supply voltage | | |
| | |
| V | 160… 260 |
| | |
| V | 160… 260 |
Working range factor supply voltage rated value | | |
| | |
| | 1… 1 |
| | |
| | 1… 1 |
Impulse voltage resistance / rated value | kV | 6 |
Recorded real power | W | 2 |
Protection class IP | | IP20 |
Electromagnetic compatibility | | IEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4 |
Resistance against vibration / according to IEC 60068-2-6 | | 1
6 Hz: 15 mm, 6
500 Hz: 2g |
Resistance against shock / according to IEC 60068-2-27 | | sinusoidal half-wave 15g / 11 ms |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Conductor-bound parasitic coupling BURST / according to IEC 61000-4-4 | | 2 kV |
Conductor-bound parasitic coupling conductor-earth SURGE / according to IEC 61000-4-5 | | 2 kV |
Conductor-bound parasitic coupling conductor-conductor SURGE / according to IEC 61000-4-5 | | 1 kV |
Electrostatic discharge / according to IEC 61000-4-2 | | 6 kV contact discharge / 8 kV air discharge |
Field-bound parasitic coupling / according to IEC 61000-4-3 | | 10 V/m |
Insulation voltage / for overvoltage category III according to IEC 60664 / with degree of pollution 3 / rated value | V | 690 |
Degree of pollution | | 3 |
Ambient temperature | | |
| °C | -25… +60 |
| °C | -40… +85 |
| °C | -40… +85 |
Galvanic isolation | | |
- between entrance and outlet
| | Yes |
| | Yes |
- between the voltage supply and other circuits
| | Yes |
|
|
Mechanical design: |
Width | mm | 22.5 |
Height | mm | 83 |
Depth | mm | 91 |
Built in orientation | | any |
Distance, to be maintained, to earthed part | | |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
Distance, to be maintained, to the ranks assembly | | |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
Distance, to be maintained, conductive elements | | |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
| mm | 0 |
Type of mounting | | snap-on mounting |
Product function / removable terminal for auxiliary and control circuit | | Yes |
Design of the electrical connection | | screw-type terminals |
Type of the connectable conductor cross-section | | |
| | 1x (0.5 ... 4 mm2), 2x (0.5 ... 2.5 mm2) |
| | |
| | Назад в раздел
|