промышленная комутационная техника

Артикул Наименование Производитель
4AM9996-8CA00-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2,5 /10,1; UPRI(V):220+/-5%; USEC(V):220; ISEC(A):11,4; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:55 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-6EA00-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2,5 /9,8; UPRI(V):220+/-5%; USEC(V):220; ISEC(A):11,4; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, RBW >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-4JA00-0NA0 MAINS TRANSFORMER; PHASES:1; PN(KVA):3; UPRI(V):600-480-460-440-415- 400-260-230; USEC(V):2X115; ISEC(A):13; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1>MAINS TRANSFORMER< >UL/CSA-RECOGNIZED< (siemens) Siemens
4AM9996-4BA00-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2,5 /10,1; UPRI(V):500+7,5%+15%; USEC(V):220; ISEC(A):11,4; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-3FA00-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):3 /15; UPRI(V):420-400-380-360; USEC(V):230-220(2X115-110); ISEC(A):13,0-13,6-26,1-27,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-2>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-2FA00-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2 /9,07; UPRI(V):420-400-380-360; USEC(V):230-220(2X115-110); ISEC(A):2,71-4,55-8,7-9,1; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 I0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1 (siemens) Siemens
4AM9996-0EE30-0JA0 ISOLATION TRANSFORMER; PHASES:1; PN(KVA):2,5; UPRI(V):400-380-360; USEC(V):152-145-121-115; ISEC(A):16,4-17,2-20,7-21,7; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-4 >UL/CSA-RECOGNIZED<>ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EE20-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2,5 /10,1; UPRI(V):230+/-5%; USEC(V):42; ISEC(A):59,5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:55 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-0EE00-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):3,15 /0; UPRI(V):480; USEC(V):230 (2 X 115); ISEC(A):13,7; F(HZ):60...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0ED30-1CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):3,15 /15,7; UPRI(V):380; USEC(V):220; ISEC(A):14,3; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /1; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-2>UL/CSA-RECOGNIZED< >CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-0ED10-0FA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):3,1 /15,4; UPRI(V):400+/-5%; USEC(V):230; ISEC(A):13,5; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4>MAINS TRANSFORMER< >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EC70-0JA0 ISOLATION TRANSFORMER; PHASES:1; PN(KVA):3; UPRI(V):230; USEC(V):230; ISEC(A):13,04; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-4 >UL/CSA-RECOGNIZED<>ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EC60-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2 /8; UPRI(V):230+/-5%; USEC(V):230; ISEC(A):8,7; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-0EC50-0JA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):3,15 /13,9; UPRI(V):690-660-575-550- 500-460-440-415-400-380; USEC(V):230; ISEC(A):13,7; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-4 >UL/CSA-RECOGNIZED< (siemens) Siemens
4AM9996-0EC30-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2,5 /9,8; UPRI(V):220+/-5%; USEC(V):230; ISEC(A):10,9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, RBW >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-0EC20-1JA0 ISOLATION TRANSFORMER; PHASES:1; PN(KVA):3; UPRI(V):480+/-5%; USEC(V):120; ISEC(A):25; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /1; TA/ISOKL:55 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-4>ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EC00-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2,5 /10,1; UPRI(V):230+/-5%; USEC(V):230; ISEC(A):10.9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:55 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-0EB80-0CA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2,5 /10,1; UPRI(V):230+/-5%; USEC(V):230; ISEC(A):10.9; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:55 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens
4AM9996-0EB70-1FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):2,476 /12,1; UPRI(V):400; USEC(V):230; 110; ISEC(A):10; 1,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /1; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EB50-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):0,607 /1,8; UPRI(V):230; USEC(V):80+/-5%+/-10%+/-15%; ISEC(A):6.6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EB40-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):3,036 /15,1; UPRI(V):230; USEC(V):400+/-15/10/5% -290+/-15/10/5% ; ISEC(A):6,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EB30-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):2,884 /14,4; UPRI(V):230; USEC(V):380+/-15/10/5% -290+/-15/10/5% ; ISEC(A):6,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EB20-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):1,142 /6,3; UPRI(V):230; USEC(V):150+/-5%+/-10%+/-15%; ISEC(A):6.6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EB10-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):3,188 /15,7; UPRI(V):230; USEC(V):420+/-5%+/-10%+/-15%- 375+/-5%+/-10%+/-15%-290+/- 5%+/-10%+/-15%-245+/-5%+/- 10%+/-15%; ISEC(A):6,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EB00-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):2,963 /14,7; UPRI(V):230; USEC(V):390+/-15/10/5% - 260+/-15/10/5% ; ISEC(A):6,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EA80-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):2,884 /14,4; UPRI(V):400; USEC(V):380-267+/-5/10/15%; ISEC(A):6,6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EA70-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):2,733 /13,6; UPRI(V):230; USEC(V):360+/-5%+/-10%+/-15%; ISEC(A):6.6; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EA50-0FA1 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):3,5 /16,4; UPRI(V):400+/-5%; USEC(V):230; ISEC(A):15,2; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /0; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:CAGE-CLAMP; INSTALLATION:SCREW; EN 61558-2-1, -2-2, -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EA30-0FA0 TRANSFORMER SITAS; PHASES:1; PN/PN(S6)(KVA):3 /15; UPRI(V):400+/-5%; USEC(V):115;115; ISEC(A):13;13; F(HZ):50...60; VECTOR GR./SHIELD WNG.:III0 /0; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; INSTALLATION:SCREW; EN 61558-2-1; -2-2; -2-4 >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< >ISOLATION TRANSFORMER< (siemens) Siemens
4AM9996-0EA20-1FA0 CONTROL CIRCUIT TRANSFORMER; PHASES:1; PN/PN(S6)(KVA):2,3 /12,1; UPRI(V):600-550-525-500- 480-460 -440-420-400-380-230-220-208- 200-190; USEC(V):230; ISEC(A):10; F(HZ):50...60; VECTOR GR./SHIELD WNG.:II0 /1; TA/ISOKL:50 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; INSTALLATION:SCREW; EN 61558-2-2, -2-2>MAINS TRANSFORMER< >UL/CSA-RECOGNIZED<>CONTROL CIRCUIT TRANSFORMER< (siemens) Siemens

Товары 1 - 30 из 13660
Начало | Пред. | 1 2 3 4 5 6 7 8 9 10 11 | След. | Конец Все