Low-Voltage Power Distribution and Electrical Installation Technology (Низковольтная техника энергораспределения и электромонтажа)
Артикул |
Наименование |
Производитель |
3VL1706-2DD36-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=63A, OVERLOAD II=600A, SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1706-2DD33-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=63A, OVERLOAD II=600A, SHORT-CIRCUIT (siemens)
|
Siemens
|
3VL1706-1EH46-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=63A, OVERLOAD II=600A, SHORT-CIRCUIT N NOT PROTECTED WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1706-1EH43-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=63A, OVERLOAD II=600A, SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
3VL1706-1EA46-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=63A, OVERLOAD II=600A, SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1706-1EA43-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=63A, OVERLOAD II=600A, SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
3VL1706-1DD36-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=50-63A, OVERLOAD II=600A, SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1706-1DD33-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=50-63A, OVERLOAD II=600A, SHORT-CIRCUIT (siemens)
|
Siemens
|
3VL1706-1DA36-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=63A, OVERLOAD II=600A, SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1706-1DA33-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=63A, RATED CURRENT IR=63A, OVERLOAD II=600A, SHORT-CIRCUIT (siemens)
|
Siemens
|
3VL1705-2EH46-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT N NOT PROTECTED WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1705-2EH43-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
3VL1705-2EA46-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1705-2EA43-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
3VL1705-2DD36-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1705-2DD33-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT (siemens)
|
Siemens
|
3VL1705-1EH46-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT N NOT PROTECTED WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1705-1EH43-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
3VL1705-1EA46-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1705-1EA43-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
3VL1705-1DD36-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=40-50A, OVERLOAD II=600A, SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1705-1DD33-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=40-50A, OVERLOAD II=600A, SHORT-CIRCUIT (siemens)
|
Siemens
|
3VL1705-1DA36-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1705-1DA33-....
|
CIRCUIT-BREAKER VL160X N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=50A, RATED CURRENT IR=50A, OVERLOAD II=600A, SHORT-CIRCUIT (siemens)
|
Siemens
|
3VL1704-2EH46-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=40A, RATED CURRENT IR=40A, OVERLOAD II=600A, SHORT-CIRCUIT N NOT PROTECTED WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1704-2EH43-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=40A, RATED CURRENT IR=40A, OVERLOAD II=600A, SHORT-CIRCUIT N NOT PROTECTED (siemens)
|
Siemens
|
3VL1704-2EA46-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=40A, RATED CURRENT IR=40A, OVERLOAD II=600A, SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL1704-2EA43-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=40A, RATED CURRENT IR=40A, OVERLOAD II=600A, SHORT-CIRCUIT N PROTECTED (siemens)
|
Siemens
|
3VL1704-2DD33-0AG1
|
Circuit-breaker VL 160X H high switching capacity ICU=70kA, 415V AC 3-pole, system protection overcurrent release TM, LI IN=40A, rated current IR=40A, overload prot. II=600A, short-circuit prot. without auxil. release alarm switch kit 1 alarm switch (1 NO (siemens)
|
Siemens
|
3VL1704-2DD36-....
|
CIRCUIT-BREAKER VL160X H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE TM, LI IN=40A, RATED CURRENT IR=40A, OVERLOAD II=600A, SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
Товары
5401 - 5430 из 5502
Начало
|
Пред.
|
174
175
176
177
178
179
180
181
182
183
184
|
След. |
Конец
| Все
|