3VL3725-2MS36-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL3725-2MS33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY R.U.S.-C.BR.C.= 70 KA, 415 V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IN=250A, RATED CURRENT TC= 10A ... 30, TIME LAG CLASS II= 6 ... 11 X IN, SHORT-CIRCUIT PROTECTION WITHOUT AUXILIARY RELEASE WITH BOX TERMINAL (siemens)
|
Siemens
|
3VL3725-2ML33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG 3PHASES/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH BOX TERMINAL (siemens)
|
Siemens
|
3VL3725-2MH36-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL3725-2MH33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH BOX TERMINAL (siemens)
|
Siemens
|
3VL3725-2MG33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG 3PHASES/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH BOX TERMINAL (siemens)
|
Siemens
|
3VL3725-2MF33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU12, LIG 3PHASES/3WIRES IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE WITH BOX TERMINAL (siemens)
|
Siemens
|
3VL3725-2LS36-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LS36-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LS33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LS33-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IR=100...250A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LF46-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 XIR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LF46-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 XIR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LF43-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 XIR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LF43-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 XIR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LE36-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LE36-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LE33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LE33-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LB36-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LB36-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LB33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LB33-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LA46-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LA46-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LA43-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2LA43-....
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU= 70KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 250A, RATED CURRENT IR= 100...250A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. BOX TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL3725-2CP33-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 3 POLE, MOTOR/GENERATOR PROTECTION OVERCURRENT RELEASE LCD ETU40M, LI IN=250A, RATED CURRENT IR=100-250A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITHOUT AUXILIARY RELEASE WITH BOX TERMINAL (siemens)
|
Siemens
|
3VL3725-2CN46-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL3725-2CN43-0A..
|
CIRCUIT-BREAKER VL 250H HIGH SWITCHING CAPACITY ICU=70KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=250A, RATED CURRENT IR=100-250A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE WITH BOX TERMINAL (siemens)
|
Siemens
|