Low-Voltage Power Distribution and Electrical Installation Technology (Низковольтная техника энергораспределения и электромонтажа)
Артикул |
Наименование |
Производитель |
3VL2710-1LS33-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IR= 40...100A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LS33-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, MOTOR PROTECTION OVERCURRENT RELEASE ETU30M, LI IR= 40...100A, OVERLOAD PROTECTION, TC= 10A ... 30, II= 6 / 8 / 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LF46-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. SCREW TERMINAL W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LF46-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W. SCREW TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LF43-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LF43-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LE36-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LE36-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LE33-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LE33-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU20, LSI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, ISD=1.5 TO 10 X IR, II=11 X IN SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LB36-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LB36-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W. SCREW TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LB33-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LB33-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 3-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LA46-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. SCREW TERMINAL W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LA46-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W. SCREW TERMINAL MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LA43-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED W/O AUXILIARY RELEASE MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1LA43-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU= 55KA, 415V AC 4-POLE, PLANT PROTECTION OVERCURRENT RELEASE ETU10, LI IN= 100A, RATED CURRENT IR= 40...100A, OVERLOAD PROTECTION, II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION N-PROTECTED MARINE APPROVAL FOR LRS, DNV AND GL (siemens)
|
Siemens
|
3VL2710-1CP36-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, MOTOR/GENERATOR PROTECTION OVERCURRENT RELEASE LCD ETU40M, LI IN=100A, RATED CURRENT IR=40-100A, OVERLOAD II=1,25TO11XIN, SHORT CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1CN46-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1CN46-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL2710-1CN43-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH EARTH FAULT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1CM36-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1CM36-....
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION (siemens)
|
Siemens
|
3VL2710-1CM33-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/4WIRES WITH PIGTAIL IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1CL36-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU42, LSIG 3PHASES/3WIRES IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1CJ46-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1CJ43-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1CH36-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 3 POLE, LINE PROTECTION OVERCURRENT RELEASE LCD ETU40, LI/LS/LSI IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
3VL2710-1BH46-0A..
|
CIRCUIT-BREAKER VL 160N STANDARD SWITCHING CAPACITY ICU=55KA / 415 V AC 4 POLE, LINE PROTECTION OVERCURRENT RELEASE ETU22, LSIG IN=100A, RATED CURRENT IR=40-100A, OVERLOAD ISD=1,5TO10XIR, II=11XIN SHORT-CIRCUIT N PROTECTED WITH SCREW CONNECTION WITHOUT AUXILIARY RELEASE (siemens)
|
Siemens
|
Товары
1711 - 1740 из 5502
Начало
|
Пред.
|
53
54
55
56
57
58
59
60
61
62
63
|
След. |
Конец
| Все
|