Low-Voltage Power Distribution and Electrical Installation Technology (Низковольтная техника энергораспределения и электромонтажа)
Артикул |
Наименование |
Производитель |
3VL2115-2JM30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-2JM30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-2JH30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-2JH30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-2GH30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-2GH30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-2GE30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-2GE30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-2GD30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-2GD30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-2GB30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-2GB30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-1KN30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3B150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 150A, RATED CURRENT II= 800...1600A SHORT-CIRCUIT PROTECTION IR= 150A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-1JM30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-1JM30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3E150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-1JH30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-1JH30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3D150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE LCD ETU, LI/LS/LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.25 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-1GH30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-1GH30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3U150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-1GE30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-1GE30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3P150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LSI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT ISD=1.5 TO 10 X IR, II=11X IN SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-1GD30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-1GD30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3X150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LIG TU= 40 DEGR. CELSIUS 3 PHASES/4 CABLES IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2115-1GB30-0A..
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES W/O AUX. RELEASE (siemens)
|
Siemens
|
3VL2115-1GB30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3N150) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE ETU, LI TU= 40 DEGR. CELSIUS IN= 150A, RATED CURRENT II= 1.25 TO 11 X IN, SHORT-CIRCUIT PROTECTION IR= 60-150A OVERCURRENT REL. F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2112-3KN30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. LDX3B125) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 125A, RATED CURRENT II= 625...1250A SHORT-CIRCUIT PROTECTION IR= 125A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2112-2KN30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3B125) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 125A, RATED CURRENT II= 625...1250A SHORT-CIRCUIT PROTECTION IR= 125A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2112-1KN30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. NDX3B125) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 STANDARD SWITCHING CAPACITY 3-POLE, NEMA RATING 35KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 125A, RATED CURRENT II= 625...1250A SHORT-CIRCUIT PROTECTION IR= 125A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2111-3KN30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. LDX3B110) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 VERY HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 100KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 110A, RATED CURRENT II= 550...1100A SHORT-CIRCUIT PROTECTION IR= 110A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
3VL2111-2KN30-....
|
CIRCUIT-BREAKER VL 150 UL; TYPE DG (CAT NO. HDX3B110) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER TO UL489 HIGH SWITCHING CAPACITY 3-POLE, NEMA RATING 65KA/480V, (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=< 110A, RATED CURRENT II= 550...1100A SHORT-CIRCUIT PROTECTION IR= 110A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES (siemens)
|
Siemens
|
Товары
2041 - 2070 из 5502
Начало
|
Пред.
|
64
65
66
67
68
69
70
71
72
73
74
|
След. |
Конец
| Все
|