MASTER/EMER. STOP SWITCH 3-POLE IU=16 P/AC-23A WITH 400V=7.5KW 1 PE TERMINAL INSULATION-ENCLOSED IP65 INCH SCREW CONNECTION "2X 1/2"" OR 2X 3/4"" TOP+BOTTO ROT. MECHANISM RED/YELLOW

Артикул: 3LD2064-0TB53-0US1
Производитель: Siemens


Наименование продукта
MASTER/EMER. STOP SWITCH 3-POLE IU=16 P/AC-23A WITH 400V=7.5KW 1 PE TERMINAL INSULATION-ENCLOSED IP65 INCH SCREW CONNECTION "2X 1/2"" OR 2X 3/4"" TOP+BOTTO ROT. MECHANISM RED/YELLOW
Жизненный цикл продукта
Разрешение на поставку Постепенное снятие продукта с производства Снятие продукта с производства Окончательное снятие продукта с производства
2003-10-01 2008-01-25 2008-02-01 2008-03-01
Similar to image
MASTER/EMER. STOP SWITCH 3-POLE IU=16 P/AC-23A WITH 400V=7.5KW 1 PE TERMINAL INSULATION-ENCLOSED IP65 INCH SCREW CONNECTION "2X 1/2"" OR 2X 3/4"" TOP+BOTTO ROT. MECHANISM RED/YELLOW
 
General technical details:
product brand name   SENTRON
product designation   main and EMERGENCY-OFF switches
Type from device   fixed mounting
Design of the operating mechanism   rotary actuator, red/yellow
Protection class IP   IP65
Number of poles   3
Acceptability for application    
  • switch disconnector
  Yes
  • main switch
  Yes
  • safety cut-out switch
  Yes
  • emergency stop switch
  Yes
  • maintenance/repair switch
  Yes
Product equipment / interlock   Yes
Type of the driving mechanism / motor drive   No
Product extension / optional    
  • motor drive
  No
  • voltage trigger
  No
Ambient temperature / during operating °C -25 +55
Insulation voltage / rated value V 690
Impulse voltage resistance / rated value V 6,000
Active power loss / per conductor / typical W 0.5
Mechanical operating cycles as operating time / of the main contacts / typical   100,000
Protection against electrical shock   finger-safe
Item designation / according to DIN EN 61346-2   S
Item designation / according to DIN 40719 extendable after IEC 204-2 / according to IEC 750   S
 
Main circuit:
   
Continuous current / rated value A 16
Operating current / at AC-21 / rated value A 16
Short-time current resistance (Icw) / at 690 V / limited to 1 s / rated value A 340
Operating frequency Hz 50 60
Operating voltage / at 50/60 Hz / for AC / rated value V 690
Service power / at AC-3    
  • at 400 V / rated value
kW 5.5
  • at 690 V / rated value
kW 5.5
Service power / at AC-23 A    
  • at 400 V / rated value
kW 7.5
  • at 690 V / rated value
kW 7.5
Operating cycles / maximum 1/h 50
 
Auxiliary circuit:
   
Number of NC contacts / for auxiliary contacts   0
Number of NO contacts / for auxiliary contacts   0
Number of change-over switches / for auxiliary contacts   0
Continuous current / of the auxiliary contact / rated value A 10
Operating voltage / of the auxiliary contacts / for AC / maximum V 500
Insulation voltage / of the auxiliary switch / rated value V 500
 
Short-circuit:
   
Design of the fuse link / for short-circuit protection of the main circuit / necessary   fuse gL/gG: 20 A
Design of the fuse link / for short-circuit protection of the auxiliary switch / required   fuse gL/gG: 10 A
 
Installation/mounting/dimensions:
   
Type of mounting   floor mounting
  • front mounting
  No
  • front mounting with central fixation
  No
  • front mounting with 4-hole fixation
  No
  • series installation
  No
  • Rail installation
  No
Width mm 100
Height mm 164
Depth mm 118
 
Connection type:
Design of the electrical connection / for main current circuit   connection terminals
Design of the electrical connection / for auxiliary contact   connection terminals
Type of the connectable conductor cross-section / for main contacts    
  • solid
  1 ... 6 mm2
  • finely stranded / with conductor end processing
  4 mm?
  • stranded
  1 ... 6 mm2
Type of connectable conductor cross section / for auxiliary contacts    
  • solid
  2x (0.75 to 2.5 mm2), 1x 4 mm2
  • stranded
  2x (0.75 ... 2.5 mm2), 1x 4 mm2
 
Certificates/approvals:
Verification of suitability   CSA / UL / CCC
Conductor cross section that can be connected / for main contacts / solid / minimum mm? 1
Conductor cross section that can be connected / for main contacts / solid / maximum mm? 6
Conductor cross section that can be connected / for main contacts / stranded / minimum mm? 1
Conductor cross section that can be connected / for main contacts / stranded / maximum mm? 6
Conductor cross-section that can be connected / for main contacts / stranded wire / with conductor end processing / maximum mm? 4
Conductor cross section that can be connected / for auxiliary contacts / solid / minimum mm? 0.75
Conductor cross section that can be connected / for auxiliary contacts / solid / maximum mm? 4
Conductor cross-section that can be connected / for auxiliary contact / stranded wire / with conductor end processing / minimum mm? 0.75
Conductor cross-section that can be connected / for auxiliary contact / stranded wire / with conductor end processing / maximum mm? 2.5
Conductor cross section that can be connected / for auxiliary contacts / stranded / min. mm? 0.75
Conductor cross section that can be connected / for auxiliary contacts / stranded / max. mm? 4
 
Certificates/approvals:
General Product Approval Test Certificates
 
last change:
Feb 27, 2012
Оборудование снято с производства, прямой заменой является:
Part number:3LD2064-0TB53-0US2
Notes:

Назад в раздел