| SINVERT PVS COMBINERBOX 108, ARRAY JUNCTION BOX FOR PV, 8 DC INPUTS, IP54, IEC, WITH FUSE HOLDER |
|
General technical data: |
product brand name | | SINVERT |
Product-type designation | | SINVERT PVS Combiner Box 108 |
product designation | | Terminal box |
Type of installation | | indoor installation / outdoor installation |
Protection class IP | | IP54 |
Operating resource protection class | | II (protective insulation) |
Degree of pollution | | 3 |
Installation altitude / at a height over sea level / maximum | m | 2,000 |
Ambient temperature | | |
| °C | -20… +45 |
| °C | -20… +45 |
| °C | -20… +45 |
Relative humidity / without condensation | | |
| % | 0… 50 |
RAL color number | | RAL 7035 |
Case | | |
| | Polyester |
| | Polyester |
Product characteristic / resistant to UV radiation | | Yes |
Fire classification / non-flammable | | Yes |
Product function / current measurement | | No |
Product component / pressure compensation element | | Yes |
Number of pressure compensation elements | | 1 |
Type of compensation element | | Diaphragm |
Product function / Overvoltage protection | | No |
|
Inputs: | | |
Input voltage / maximum | V | 1,000 |
Number of inputs | | 8 |
Input current / per input / maximum | A | 10 |
Product component / at input / protection | | Yes |
Type of protection / at input | | Cylinder fuse link |
Number of inputs / per protection | | 1 |
|
Outputs: | | |
Output current / maximum | A | 104 |
Product component / at output / protection | | No |
Product component / at output / disconnecting device | | No |
|
Connections: | | |
Design of the electrical connection / at the DC input | | Cage clamp terminal |
Tightening torque | | |
| N·m | 2… 2.5 |
Connectable conductor cross-section / at DC input | | |
| mm² | 0.75… 25 |
| mm² | 0.75… 25 |
| | |
- with conductor end processing
| mm² | 1.5… 25 |
| | |
- with conductor end processing
| mm² | 1.5… 25 |
Outside diameter / of cable sheath / for cable gland / at DC input | | |
| mm | 4.5… 10 |
Type of electrical terminal / at DC output | | Stud terminal |
Type of thread / for terminal screw / at DC output | | M8 |
Tightening torque | | |
| N·m | 6… 12 |
Connectable conductor cross-section / at DC output | | |
| | |
- with conductor end processing
| mm² | 2.5… 95 |
| | |
- with conductor end processing
| mm² | 2.5… 95 |
Outside diameter / of cable sheath / for cable gland / at DC output | | |
| mm | 15… 21 |
Design of the electrical connection / for grounding | | Cage clamp terminal |
Tightening torque | | |
| N·m | 1.2… 2.4 |
Connectable conductor cross-section / for grounding | | |
| mm² | 1.5… 16 |
| mm² | 1.5… 25 |
| | |
- with conductor end processing
| mm² | 1.5… 16 |
| | |
- with conductor end processing
| mm² | 1.5… 16 |
Outside diameter / of cable sheath / for cable gland / for grounding | | |
| mm | 4.5… 10 |
|
Installation/mounting/dimensions: |
Built in orientation | | Vertical |
Type of mounting | | wall mounting |
Cable gland version | | from below |
Width | mm | 600 |
Depth | mm | 132 |
Height | mm | 400 |
Weight | kg | 10.5 |
|
Certificates/approvals: |
Verification of suitability | | CE |