7MA30
Артикул |
Наименование |
Производитель |
7MA3020-8BA
|
SIPAN O2-MP MEASURING INSTRUMENT WITH MICROPROCESSOR, SEALED KEYBOARD, DIGITAL DISPLAY AND LIMIT MONITOR IN PLASTIC HOUSING, POWER SUPPLY DC 24 V
|
Siemens
|
7MA3034-.....-....
|
SIPAN 34 ANALYZER FOUR-WIRE SYSTEM FOR MEASUREM. OF DISSOLVED OXYGEN, MICROPROC. CONTROLLED WITH ILLUMINATED GRAPHIC DISPLAY, MEMBRANE KEYBOARD, MENU-BASED OPERATION (5 LANGUAGES), DIAGNOSTIC SOFT- WARE,MANUAL ON CD (5 LANGUAGES) LOGBOOK, TEMPERATURE COMPENSATION, COMPENSATION OF BAROMETRIC PRESSURE, 1 PARAMETER SET, 1 SIGNAL OUTPUT: 0/4 TO 20 MA, 1 ALARM CONTACT, 1 LIMIT CONTACT, 2 DIAGNOSTIC CONTACTS
|
Siemens
|
7MA3030-.....
|
SIPAN 3 MEASURING INSTRUMENT FOR THE MEASUREMENT OF DISSOLVED OXYGEN, STANDARD VERSION,MICROPROCESSOR BASED WITH ILLUMINATED GRAPHIC DISPLAY, MENU CONTROL, DIAGNOSTIC SOFTWARE, TOUCH PAD KEYBOARD, TREND DISPLAY, CONCENTRATION DISPLAY, TEMPERATURE COMPEN- SATION, LOGBOOK, 1 PARAMETER SET, 1 SIGNAL OUTPUT: 0/4 TO 20 MA, 1 ALARM CONTACT AND 1 LIMIT CONTACT
|
Siemens
|
7MA3020-8BB
|
SIPAN O2-MP MEASURING INSTRUMENT WITH MICROPROCESSOR, SELAED KEYBOARD, DIGITAL DISPLAY AND LIMIT MONITOR IN PLASTIC HOUSING, POWER SUPPLY AC 24/115/230 V
|
Siemens
|
7MA3040-8AD
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR THE MEASUREMENT OF DISSOLVED O2, MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH MULTI- SEGMENT DISPLAY, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, 1 PARAMETER SET, POWER SUPPLY: DC 24 V, IN FIELD HOUSING COMMUNICATION VIA PROFIBUS PA
|
Siemens
|
7MA3031-.....-....
|
FOR THE MEASUREMENT OF
|
Siemens
|
7MA3040-8AA
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR THE MEASUREMENT OF DISSOLVED O2, MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH MULTI- SEGMENT DISPLAY, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, 1 PARAMETER SET, POWER SUPPLY: DC 24 V, IN FIELD HOUSING STANDARD VERSION, 1 SIGNAL OUTPUT, 4 TO 20 MA WITHOUT INTERFACE
|
Siemens
|
7MA3040-8AC
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR THE MEASUREMENT OF DISSOLVED O2, MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH MULTI- SEGMENT DISPLAY, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, 1 PARAMETER SET, POWER SUPPLY: 2 SIGNAL OUTPUTS WITH HART INTERFACE FIRST SIGNAL OUTPUT: 4 TO 20 MA SECOND SIGNAL OUTPUT: TEMPERATURE OR SWITCHING CONTACT FOR LIMIT OR CLEANING OR WARNING
|
Siemens
|
7MA3040-8AB
|
SIPAN 32 ANALYZER TWO-WIRE SYSTEM FOR THE MEASUREMENT OF DISSOLVED O2, MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH MULTI- SEGMENT DISPLAY, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, 1 PARAMETER SET, POWER SUPPLY: DC 24 V, IN FIELD HOUSING 1 SIGNAL OUTPUT, 4 TO 20 MA WITH HART INTERFACE
|
Siemens
|
7MA3041-8AA
|
SIPAN 32X ANALYZER WITH EX PROTECTION, INTRINSICALLY-SAFE VERSION, II 2G EEX IA IIC T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR THE MEASUREMENT OF DISSOLVED O2, MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH MULTI- SEGMENT DISPLAY, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, 1 PARAMETER SET, POWER SUPPLY: DC 24 V, IN FIELD HOUSING STANDARD VERSION, 1 SIGNAL OUTPUT, 4 TO 20 MA WITHOUT INTERFACE
|
Siemens
|
7MA3041-8AC
|
SIPAN 32X ANALYZER WITH EX- PROTECTION, INTRINSICALLY-SAFE VERSION, II 2G EEX IA IIC T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR THE MEASUREMENT OF DISSOLVED O2, MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH MULTI- SEGMENT DISPLAY, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, 1 PARAMETER SET, POWER SUPPLY: 2 SIGNAL OUTPUTS WITH HART INTERFACE, 1. SIGNAL OUTPUT: 4 TO 20 MA, 2. SIGNAL OUTPUT: TEMP. OR SWITCHING CONTACT FOR LIMIT OR CLEANING OR WARNING
|
Siemens
|
7MA3041-8AB
|
SIPAN 32X ANALYZER WITH EX PROTECTION, INTRINSICALLY- SAFE VERSION, II 2 G EEX IA II C T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR THE MEASUREMENT OF DISSOLVED O2, MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH MULTI- SEGMENT DISPLAY, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, 1 PARAMETER SET, POWER SUPPLY: DC 24 V, IN FIELD HOUSING 1 SIGNAL OUTPUT, 4 TO 20 MA WITH HART INTERFACE
|
Siemens
|
7MA3041-8AD
|
SIPAN 32X ANALYZER WITH EXPLOSION PROTECTION, INTRINSICALLY-SAFE VERSION, II 2 G EEX IA IIC T4, CABLE LENGTH TO SENSOR MAX. 5 M TWO-WIRE SYSTEM FOR THE MEASUREMENT OF DISSOLVED O2, MICROPROCESSOR-CONTROLLED, MEMBRANE KEYBOARD WITH MULTI- SEGMENT DISPLAY, MENU-BASED OPERATION, LOGBOOK, MANUAL ON CD (5 LANGUAGES), CONCENTRATION DISPLAY, TEMPERATURE COMPENSATION, DIAGNOSTIC SOFTWARE, 1 PARAMETER SET, POWER SUPPLY: DC 24 V, IN FIELD HOUSING COMMUNICATION VIA PROFIBUS PA
|
Siemens
|
|