AS-Interface sensor/actuator module | VAA-2*EA-G2-ZE/E2

Артикул: VAA-2*EA-G2-ZE/E2
Производитель: Pepperl-Fuchs


Not available for purchase, If you need assistance please contact us sales@sm-industry.ru
Оборудование снято с производства, для уточнения замены свяжитесь с нами sales@sm-industry.ru

  • AS-Interface certificate
  • Protection degree IP67
  • Addressing jack
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Communication monitoring, turn-off
  • Two MOVI-SWITCH-1E, controllable by SEW
  • Inputs for 2- and 3-wire sensors
  • Power supply of inputs and outputs from the module
  • Ground connection (PE) possible
  • Function display for bus, inputs and outputs
  • Monitoring of sensor overloads

Datasheet as PDF in following languages:


Technical Data: VAA-2*EA-G2-ZE/E2

Product Description
G2 flat module for motor starter
2 inputs/2 electronic outputs
General specifications
Slave typeStandard slave
AS-Interface specificationV2.1
Required master specification≥ V2.0
UL File NumberE87056
Indicators/operating means
LED FAULTerror display; LED red
red: communication error or address is 0
red flashing: overload of sensor supply
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 2 LED yellow
LED OUTSwitching state (output); 2 LED yellow
Electrical specifications
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current≤ 30 mA (without sensors) / max. 180 mA
Protection classIII
Input
Number/Type2 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface
Voltage21 ... 31 V
Current loading capacity≤ 150 mA (TB ≤ 40 В°C),
≤ 120 mA (TB ≤ 60 В°C), short-circuit protected
Input current≤ 8 mA (limited internally)
Switching point
0 (unattenuated)≤ 1.5 mA
1 (attenuated)≥ 4.5 mA
Output
Number/Type2 electronic outputs, PNP
Supplyfrom AS-Interface
Currentlimited by the current loading capacity of the module
Programming instructions
ProfileS-3.F
IO code3
ID codeF
Data bits (function via AS-Interface) input output
D0 IN1 -
D1 IN2 -
D2 - OUT3
D3 - OUT4
Parameter bits (programmable via AS-i)function
P0communication monitoring
P0 = 1 (basic setting), monitoring = ON, i.e. if communication fails, the outputs are de-energised
P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2not used
P3not used
Compliance with standards and directives
Directive conformity
EMC Directive 89/336/EECEN 61000-6-2:2001, EN 61000-6-4:2001, EN 50295:1999
Standard conformity
Noise immunityEN 61000-6-2:2001
Emitted interferenceEN 61000-6-4:2001
AS-InterfaceEN 50295:1999
InputEN 61131-2
Protection degreeEN 60529
Ambient conditions
Ambient temperature-25 ... 60 В°C (-13 ... 140 В°F)
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Mechanical specifications
Protection degreeIP67
ConnectionCable piercing method
flat cable yellow/flat cable black
inputs/outputs: M12 round connector
Mass100 g
MountingMounting base


Назад в раздел