  • Addressing jack
  • Flat cable connection with cable piercing technique, variable flat cable guide
  • Communication monitoring
  • 2 safe inputs for mechanical contacts such as EMERGENCY-STOP switch
  • Power supply of inputs from the module
  • Function display for bus and inputs

Datasheet as PDF in following languages:


Technical Data: VAA-2E-G2-S

Product Description
G2 safety module
2 safety-related inputs
General specifications
Slave typeSafety-Slave
AS-Interface specificationV2.1
Required master specification≥ V2.0
UL File NumberE87056
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
MTTFd200 a
Indicators/operating means
LED FAULTerror display; LED red
red: communication error or address is 0
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 2 LED yellow
Electrical specifications
Rated operating voltage26.5 ... 31.6 V PELV from AS-Interface
Rated operating current≤ 70 mA
Protection classIII
Input
Number/Type2 safety-related inputs for mechanical contacts, cross-circuit monitored:
2 single-channel contacts: up to category 2 in accordance with EN 954-1 or
1, 2-channel contact: up to category 4 in accordance with EN 954-1
Cable length must not exceed 30 m per input.
Supplyfrom AS-Interface
Voltage20 ... 30 V DC pulsed
Current loading capacityinput current limited ≤ 15 mA,
overload and short-circuit resistant
Programming instructions
ProfileS-0.B
IO code0
ID codeB
ID1 codeF
ID2 code0
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 -
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0not used
P1not used
P2not used
P3not used
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/ECEN 61326, EN 50295, EN 61496-1
Standard conformity
Electromagnetic compatibilityEN 61000-6-2, EN 61000-4-5 1 kV asymmetric, criterion B, EN 61000-6-4
Emitted interferenceEN 61000-6-4:2001
Insulation coordinationEN 50178:1998
Functional safetyEN 954-1:1996 (up to category 4), BIA Final Draft "Proposal for a principle to the verification and certification of field busses for transmission of safety related signals" 28.05.2000, IEC 61508 up to SIL3
Protection degreeEN 60529:2000
Fieldbus standardEN 50295:1999, IEC 62026-2:2006
Electrical safetyEN 60947-5-1:2005 , IEC 60204-1:2007
Ambient conditions
Ambient temperature-25 ... 55 В°C (-13 ... 131 В°F)
Storage temperature-25 ... 85 В°C (-13 ... 185 В°F)
Mechanical specifications
Protection degreeIP67
ConnectionCable piercing method
flat cable yellow/flat cable black
inputs/outputs: M12 round connector
Material
HousingPBT
Mass100 g
MountingMounting base