Control interface for the connection of up to 4 read/write heads
General specifications
Number of read/write heads
max. 4
Indicators/operating means
LED green/yellow
read/write head (4 pieces, 1 for each head) green: command an read/write head active yellow: approx. 1 second long, if command was successfully executed
LED ERR
red: hardware or bus fault
LED PWR
green: Power on
LC display
two-line multi-function display with 12 characters per line display of status, operating information and dispaly of connected read/write heads as additional pictograms
Button
3 keys: menu up, menu down, return for configuration of the control interface and the read/write heads and activation of read commands
Electrical specifications
Rated operating voltage
20 ... 30 V DC PELV (protection class 3 in acc. with VDE 0106/IEC 364-4-41)
Ripple
≤ 10 % at 30 V DC
Current consumption
at UB = 24 V DC: < 300 mA with 1 read/write head < 750 mA with 4 active read/write heads
Power consumption
8 W
Electrical isolation
Basic insulation according to DIN EN 50178, rated insulation voltage of AC 50 V