Артикул: RSD-TI2-Ex8
Производитель: Pepperl-Fuchs
|
|
- 8-channel
- Inputs EEx ia IIC
- Device installation in Zone 1, Zone 2, or Zone 22
- Module can be exchanged under voltage in Zone 1 (hot swap)
- Connection of resistance thermometers Pt100 or Ni100 in 2-, 3- or 4-wire connection
- Connection of thermocouples, type B, E, J, K, L, N, R, S or T
- Connection of other resistive sensors, mV sources or thermocouples possible. Linearization adjustable via software
- Lead breakage (LB) monitoring for each field circuit
- Filter cut-off frequency can be programmed from 0.2 Hz to 10 Hz
- EMC acc. to NAMUR NE 21
Datasheet as PDF in following languages: Technical Data: RSD-TI2-Ex8Supply | Connection | terminals 34, 50 V+; 35, 51 V- | Rated voltage | 8.88 ... 9.5 V | Power loss | 1.6 W | Power consumption | 1.6 W | Internal bus | Connection | backplane bus | Interface | manufacturer specific bus | Cycle time | 1.6 ms | Input | Connection | terminals 0+, 1H, 2L, 3-; 4+, 5H, 6L, 7-; 8+, 9H, 10L, 11-; 12+, 13H, 14L, 15-; 17+, 18H, 19L, 20-; 21+, 22H, 23L, 24-; 25+, 26H, 27L, 28-; 29+, 30H, 31L, 32- | Input signal | suitable for: Pt100, Pt200, Ni100, Ni200, Ni120 Minco, Cu10 Minco thermocouples type B, E, J, K, N, R, S, T and mV sources | Lead resistance | max. 10 Ω for each connection | Line fault detection | lead monitoring for all lines and CJC | Transfer characteristics | Resolution | 16 Bit | Step response | 65 ms (0 ... 90 % of the measured value by smallest filter setting) | Directive conformity | Electromagnetic compatibility | | | Directive 2004/108/EC | EN 61326-1:2006 | Explosion protection | | | Directive 94/9/EC | EN 60079-0:2006, EN 60079-11:2007, EN 60079-26:2004 , EN 61241-0:2006, EN 61241-1:2006 | Standard conformity | Insulation coordination | EN 50178 | Electrical isolation | EN 60079-11:2007 | Electromagnetic compatibility | NE 21:2006 | Protection degree | IEC 60529 | Climatic conditions | IEC 60721 | Ambient conditions | Classification | 3K3 | Ambient temperature | -20 ... 70 В°C (-4 ... 158 В°F) | Storage temperature | -20 ... 100 В°C (-4 ... 212 В°F) | Relative humidity | 95 % non-condensing | Shock resistance | 15 g peak, 11 ms period | Vibration resistance | 2 g , 10 ... 500 Hz according to IEC 60068-2-6 | Damaging gas | acc. to ISA-S71.04-1985, severity level G3 | Mechanical specifications | Connection type | Terminals | Core cross-section | max. 2.5 mm2 | Protection degree | IP20, for on-site installation a separate housing is required with a minimum of IP54 | Mass | approx. 245 g | Mounting | DIN rail mounting | Data for application in connection with Ex-areas | EC-Type Examination Certificate | DMT 98 ATEX E 015 X , for additional certificates see www.pepperl-fuchs.com | | Group, category, type of protection | II (1)2G EEx ia/ib IIB/IIC II (1D)(2D) | | Temperature class | T4 | Supply | only in connection with the power units RSD2-PSD2-Ex4.34, RSA6-PSD-Ex4.34 | Input | | | Voltage | 9 V | | Current | 38 mA | | Power | 86 mW | | External capacitance | 4.9 µF | | External inductance | 20 mH | | L/R-ratio | 0.4 mH/Ω | Internal bus | customer specific | Statement of conformity | | | Group, category, type of protection, temperature class | II 3D IP54 T 90В°C | Electrical isolation | | | Input/input | no electrical isolation | | Input/power supply | safe electrical isolation acc. to EN 60079-11:2007, voltage peak value 60 V | | Input/Internal Bus | safe electrical isolation acc. to EN 60079-11:2007, voltage peak value 60 V | | Internal bus/power supply | safe electrical isolation acc. to EN 60079-11:2007, voltage peak value 60 V |
|