Logic Control Units, Rotation Speed Monitors | KFD2-DW-Ex1.D

Артикул: KFD2-DW-Ex1.D
Производитель: Pepperl-Fuchs


Not available for purchase, If you need assistance please contact us sales@sm-industry.ru
Оборудование снято с производства, для уточнения замены свяжитесь с нами sales@sm-industry.ru

  • Control circuit EEx ia IIC
  • Lead breakage (LB) and short-circuit (SC) monitoring
  • 1 signal output with 1 changeover contact
  • 1 serially switched output
  • 1 error message output
  • LC display
  • Start-up override
  • Preferred direction of the output relay, switching delay, hysteresis and direction of action adjustable

Datasheet as PDF in following languages:


Technical Data: KFD2-DW-Ex1.D

Product Description
24 V DC:
Supply
ConnectionPower Rail or terminals 17+, 18-
Rated voltage20 ... 35 V DC
Ripple≤ 10 %
Rated current≤ 93 mA
Input
Connectionintrinsically safe: terminals 1+, 2+, 3-
non-intrinsically safe: terminal 15
Rated valuesacc. to EN 60947-5-6 (NAMUR), see system description for electrical data
Open circuit voltage/short-circuit currentapprox. 8 V DC / approx. 8 mA
Switching point/switching hysteresis1.2 ... 2.1 mA / approx. 0.2 mA
Pulse/Pause ratiomin. 0.1 ms / min. 0.1 ms
Signal level1-signal: 15 ... 35 V DC (1 mA at 24 V DC)
0-signal: 0 ... 5 V DC or open input
Functionstartup override
Line fault detectionbreakage I = 0.05 ... 0.15 mA , short-circuit 6.2 ... 7.4 mA
Output
Connectionoutput I: terminals 7+, 8- ; output II: terminals 9+, 13- ; output III: terminals 10, 11, 12
Output Ifault signal ; electronic output, passive
Output IIserial switching ; electronic output, passive
Output IIIsignal ; relay
Contact loading250 V AC / 2 A /cos φ ≥ 0.7; 40 V DC / 2 A resistive load
Mechanical life5 x 107 switching cycles
Directive conformity
Electromagnetic compatibility
Directive 89/336/EECon request
Ambient conditions
Ambient temperature-25 ... 65 В°C (-13 ... 149 В°F)
Mechanical specifications
Protection degreeIP20
Massapprox. 270 g
Data for application in connection with Ex-areas
EC-Type Examination CertificatePTB No. Ex-89.C.2145 ; for additional certificates refer to the approval list
Group, category, type of protection[EEx ia] IIC resp. [EEx ia] IIB
Directive conformity
Directive 94/9/ECon request


Назад в раздел