3VT8

Àðòèêóë Íàèìåíîâàíèå Ïðîèçâîäèòåëü
3VT8563-3FA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 Î×. ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. L ICU = 65 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=630A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 10 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8563-3EA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 Î×. ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. L ICU = 65 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=630A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8563-3EA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 Î×. ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. L ICU = 65 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=630A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8563-3AA04-...0 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 Î×. ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. L ICU = 65 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 630A, OVERLOAD PROT. II = 6300A, SHORT-CIRCUIT PROT. SIEMENS
3VT8431-1DA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 220.5..315A,OVERLOAD PROT. II = 3780A, SHORT-CIRCUIT PROT. SIEMENS
3VT8431-1CA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 315A, OVERLOAD PROT. II = 3780A, SHORT-CIRCUIT PROT. SIEMENS
3VT8431-1BA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 220.5..315A,OVERLOAD PROT. II = 3150A, SHORT-CIRCUIT PROT. SIEMENS
3VT8431-1BA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 220.5..315A,OVERLOAD PROT. II = 3150A, SHORT-CIRCUIT PROT. SIEMENS
3VT8431-1AA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 315A, OVERLOAD PROT. II = 3150A, SHORT-CIRCUIT PROT. SIEMENS
3VT8431-1AA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 315A, OVERLOAD PROT. II = 3150A, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-2EA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. H ICU = 50 KA, 415/440 VAC 4- ÏÎËÞÑÀ,SYSTEM/MOTOR PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=250A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8550-1FA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=500A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 10 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8550-1EA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=500A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8550-1EA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=500A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8550-1AA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 500A, OVERLOAD PROT. II = 5000A, SHORT-CIRCUIT PROT. SIEMENS
3VT8550-1AA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 500A, OVERLOAD PROT. II = 5000A, SHORT-CIRCUIT PROT. SIEMENS
3VT8540-3FA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 Î×. ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. L ICU = 65 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 10 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8540-3FA03-...0 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT630 Î×. ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. L ICU = 65 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 10 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8440-1EA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ,SYSTEM/MOTOR PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=400A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8440-1DA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 280..400A, OVERLOAD PROT. II = 4800A, SHORT-CIRCUIT PROT. SIEMENS
3VT8440-1CA03-...0 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 400A, OVERLOAD PROT. II = 4800A, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-2EA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. H ICU = 50 KA, 415/440 VAC 3- ÏÎËÞÑÀ,SYSTEM/MOTOR PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=250A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-2DA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. H ICU = 50 KA, 415/440 VAC 3- ÏÎËÞÑÀ, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 175..250A, OVERLOAD PROT. II = 3000A, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-2CA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. H ICU = 50 KA, 415/440 VAC 3- ÏÎËÞÑÀ, MOTOR PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 250A, OVERLOAD PROT. II = 3000A, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-2BA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. H ICU = 50 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 175..250A, OVERLOAD PROT. II = 2500A, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-2BA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. H ICU = 50 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 175..250A, OVERLOAD PROT. II = 2500A, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-2AA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. H ICU = 50 KA, 415/440 VAC 4- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 250A, OVERLOAD PROT. II = 2500A, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-2AA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÂÛÑÎÊ.ÎÒÊË.ÑÏÎÑ. H ICU = 50 KA, 415/440 VAC 3- ÏÎËÞÑÀ, SYSTEM PROTECTION THERMAL-MAGNETIC TRIP UNIT, IR = 250A, OVERLOAD PROT. II = 2500A, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-1EA04-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 4- ÏÎËÞÑÀ,SYSTEM/MOTOR PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=250A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS
3VT8425-1EA03-...2 ÀÂÒ. ÂÛÊËÞ×ÀÒÅËÜ VT400 ÑÒÄ. ÎÒÊË.ÑÏÎÑ. N ICU = 35 KA, 415/440 VAC 3- ÏÎËÞÑÀ,SYSTEM/MOTOR PROTECTION ÐÀÑÖÅÏÈÒÅËÜ ÌÀÊÑ.ÒÎÊÀ ÝËÅÊÒÐ., IN=250A, IR = 0.4..1 X IN, OVERLOAD PROT. II = 2;5;10;12 X IN, SHORT-CIRCUIT PROT. SIEMENS

Òîâàðû 61 - 90 èç 292
Íà÷àëî | Ïðåä. | 1 2 3 4 5 6 7 8 9 10 | Ñëåä. | Êîíåö Âñå