SIMODRIVE 611 INFEED/REGEN.FEEDBACK MODULE 120/156 KW, CLOSED-LOOP CONTROL INTERNAL COOLING

Артикул: 6SN1145-1BB00-0FA1
Производитель: Siemens


Наименование продукта
SIMODRIVE 611 INFEED/REGEN.FEEDBACK MODULE 120/156 KW, CLOSED-LOOP CONTROL INTERNAL COOLING
Жизненный цикл продукта
Разрешение на поставкуПостепенное снятие продукта с производстваСнятие продукта с производстваОкончательное снятие продукта с производства
1998-07-10
General Data
product name closed-loop control infeed/regenerative feedback module
Unit type infeed module
Function status 1
Cooling internal / hose
cooling method separate cooling
degree of protection With internal heat dissipation: IP 20 / With hose heat dissipation: IP 20 for the electronics area and IP 54 for the heatsink in the heat dissipation area
weight / approx. 29 kg
dimension / width 300 mm
dimension / height 480 mm
dimension / depth 288 mm
infeed / type closed-loop
connection / power connection 150 mm2 or 2 x 50 mm2
Connection / line connection / cross-section / max. 150 mm²
   
Electrical Data
rated output / infeed 120 kW
rated output / infeed / S3-60 % 156 kW
rated output / infeed / peak power 175 kW
rated output / regenerative feedback 120 kW
rated output / regenerative feedback / peak power 175 kW
rated current In 202 A
rated current In / Input / at undervoltage 224.5 A
Rated current In / Output / Peak current 294 A
Input voltage 400 V 3-phase AC -10% to 480 V 3-phase AC + 6 %
Output voltage 600V / 625V / 680V
power frequency / min. 50 Hz
power frequency / tolerance / min. -10 %
power frequency / max 60 Hz
power frequency / tolerance / max 10 %
Efficiency eta 0.978
charging limit 20000 µF
power factor / cos phi / sine current mode 0.98
power factor / cos phi / block current mode 0.98
power factor / cos lambda / sine current mode 0.97
power factor / cos lambda / block current mode 0.89
impedance voltage / required / maximum 3 %
   
Ambient Conditions
ambient temperature on operation / min. 0 °C
ambient temperature / during operation / max. 40 °C
ambient temperature / during operation / max. / with power reduction 55 °C
ambient temperature / when stored / min. -40 °C
ambient temperature / when stored / max. 70 °C
ambient temperature / when transported / min. -40 °C
ambient temperature / when transported / max. 70 °C
   
last change: Jan 30, 2012


Назад в раздел