1FN3100-5PK00-0AA0 PRECISION COOLER FOR PRIMARY SECTION 1FN3100-5W... COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens
1FN3100-4WE00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=900N; FMAX=2200N; VMAX_FN=497M/MIN; VMAX_FMAX=237M/MIN; IN=16,1A; IMAX=43A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED - Siemens Siemens
1FN3100-4WE00-0AA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=900N; FMAX=2200N; VMAX_FN=497M/MIN;VMAX_FMAX=237M IN=16,1A; IMAX=43A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED - Siemens Siemens
1FN3100-4WC00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=900N; FMAX=2200N; VMAX_FN=297M/MIN; VMAX_FMAX=131M/MIN; IN=10,1A; IMAX=27A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED - Siemens Siemens
1FN3100-4TP00-1AF0 COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 5 SECONDARY SECTION SEGMENTS - Siemens Siemens
1FN3100-4TP00-1AE0 COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 4 SECONDARY SECTION SEGMENTS - Siemens Siemens
1FN3100-4TP00-1AD5 COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3,5 SECONDARY SECTION SEGMENTS - Siemens Siemens
1FN3100-4TP00-1AD0 COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 3 SECONDARY SECTION SEGMENTS - Siemens Siemens
1FN3100-4TP00-1AC5 COVER BAND SEGMENTED FOR SECONDARY SECTION TRACK; FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COVER FOR 2,5 SECONDARY SECTION SEGMENTS - Siemens Siemens
1FN3100-4PK10-0AA0 PRECISION COOLER FOR PRIMARY SECTION 1FN3100-4N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens
1FN3100-4PK00-0AA0 PRECISION COOLER FOR PRIMARY SECTION 1FN3100-4W... COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens
1FN3100-4NC80-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; STYLE DEPT CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=1205N; FMAX=2040N; VMAX_FN=305M/MIN; VMAX=169M/MIN; IN=15,9A; IMAX=33,1A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED - Siemens Siemens
1FN3100-3WE00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=675N; FMAX=1650N; VMAX_FN=497M/MIN; VMAX_FMAX=237M/MIN; IN=12,1A; IMAX=32,2A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. - Siemens Siemens
1FN3100-3WC00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=675N; FMAX=1650N; VMAX_FN=277M/MIN; VMAX_FMAX=120M/MIN; IN=7,2A; IMAX=19,1A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. - Siemens Siemens
1FN3100-3PK10-0AA0 PRECISION COOLER FOR PRIMARY SECTION 1FN3100-3N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens
1FN3100-3PK00-0AA0 PRECISION COOLER FOR PRIMARY SECTION 1FN3100-3W... COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens
1FN3100-3NC00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; STYLE DEPT CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=905N; FMAX=1530N; VMAX_FN=211M/MIN; VMAX=115M/MIN; IN=8,5A; IMAX=17,6A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. - Siemens Siemens
1FN3100-2WS00-0AA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; TYPE 1FN3100-2WC00-0AA1 WITH INVERSE ELECTRIC COIL CONNECTION OF POWER AND SIGNAL IN ONE CABLE; COVER IS PREPARED FOR PLASTIC CONDUIT COUPLING; FN=450N; FMAX=1100N; VMAX-FN=297M/MIN; VMAX-FMAX=131M/MIN; IN=5.1A; IMAX=13.5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS WHEN OPERATING DIRECT MOTORS VIOLATED. - Siemens Siemens
1FN3100-2WE00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=540N; FMAX=1100N; VMAX_FN=497M/MIN; VMAX_FMAX=237M/MIN; IN=8,1A; IMAX=21,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS WHEN OPERATING DIRECT MOTORS VIOLATED. - Siemens Siemens
1FN3100-2WC00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=450N; FMAX=110N; VMAX_FN=297M/MIN; VMAX_FMAX=131M/MIN; IN=5,1A; IMAX=13,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS WHEN OPERATING DIRECT MOTORS VIOLATED. - Siemens Siemens
1FN3100-2PK10-0AA0 PRECISION COOLER FOR PRIMARY SECTION 1FN3100-2N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens
1FN3100-2PK00-0AA0 PRECISION COOLER FOR PRIMARY SECTION 1FN3100-2W... COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens
1FN3100-2NC80-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; CONTINUOUS LOAD SPECIFICATION; CONNECTION OF POWER AND SIGNAL SEPARATED; CABLES TIGHTLY MOUNTED; LENGTH 2M; FN=605N; FMAX=1020N; VMAX_FN=307M/MIN; VMAX=170M/MIN IN=8A; IMAX=16,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. - Siemens Siemens
1FN3100-1WC00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; PEAK LOAD SPECIFICATION; COVER PREPARED FOR METRIC SCREW GLAND; SEPARATE CONNECTION OF POWER AND SIGNAL; FN=200N; FMAX=490N; VMAX_FN=322M/MIN; VMAX_FMAX=138M/MIN; IN=2,4A; IMAX=6,5A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. VIOLATED. - Siemens Siemens
1FN3100-1PK10-0AA0 PRECISION COOLER FOR PRIMARY SECTION 1FN3100-1N... COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens
1FN3100-1NC00-0BA1 PRIMARY SECTION; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; STYLE DEPT CONTINUOUS LOAD SPECIFICATION; SEPARATE CONNECTION OF POWER AND SIGNAL; COVER PREPARED FOR METRIC SCREW GLAND; FN=300N; FMAX=510N; VMAX_FN=214M/MIN; VMAX=117M/MIN; IN=2,9A; IMAX=5,9A PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED. VIOLATED. - Siemens Siemens
1FN3100-0TJ01-0AA0 COMBINED CROSS CONNECTOR; FRAME SIZE 100; WITH COUPLING; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER DISTRIBUTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK - Siemens Siemens
1FN3100-0TG01-0AA0 COMBINED ADAPTER FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR INFLOW AND OUTFLOW OF WATER AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK - Siemens Siemens
1FN3100-0TF01-0AA0 COMBINED END-PIECE FOR FRAME SIZE 100; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FOR WATER-REDIRECTION AND HOLDING DOWN OF COVER BAND AT THE END OF THE SECONDARY SECTION TRACK - Siemens Siemens
1FN3900-0TC00-0AA0 END PIECE FOR SECONDARY UNIT WITH RETAINING DEV. FOR COVER COMPONENT 3-PHASE SYNCHRONOUS MOTOR; - Siemens Siemens