BQ3B080H00S01
|
3P 80A 240V CB _
|
Siemens
|
BQ3B050QX
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL QUICK CONNECT LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B070HR
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 70 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22000 AMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B050QX
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL QUICK CONNECT LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B090L
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B100Y
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 100 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 5 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL; BQ MODEL; CALIBRATION AT 400 HZ _
|
Siemens
|
BQ3B035
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B025L
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 25 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B050HL
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQH FRAME; 240 VAC AT 60 HZ; 50 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE AT 120/240 VAC; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 2.37 INCH D X 3.75 INCH H _
|
Siemens
|
BQ3B015C
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 15 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B09000S01
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _
|
Siemens
|
BQ3B080L
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B020HC
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B040C
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B035C
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 35 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B040QL
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3.75 INCH H; APPROVAL UL 489, UL 1066, CE _
|
Siemens
|
BQ3B020H
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 20 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B080HL
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B100
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 100 AMPERE; 3 POLE; TERMINAL NOT INCLUDED; FXD6 MODEL _
|
Siemens
|
BQ3B08001
|
3P 80A 240V CB _
|
Siemens
|
BQ3B100F
|
3P 100A 240V CB _
|
Siemens
|
BQ3B070YL
|
BQ3B070YL Siemens (en) _
|
Siemens
|
BQ3B060Y
|
60A3P240V 10K 400HZ CB _
|
Siemens
|
BQ3B090HL
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 90 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LINE LUG, LOAD LUG; SIZE 3 INCH W X 3 INCH D X 4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B04500S01
|
MOLDED CASE CIRCUIT BREAKER, MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 45 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL; INCLUDES 120 VAC SHUNT TRIP _
|
Siemens
|
Q33001
|
3P 30A 240V CB _
|
Siemens
|
BQ3B040H
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 40 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 22 KILOAMPERE; TERMINAL LOAD LUG; SIZE 3 INCH W X 3 INCH D X 3-3/4 INCH H; BQ MODEL _
|
Siemens
|
BQ3B045H
|
3P 45A 240V CB _
|
Siemens
|
BQ3B100
|
MOLDED CASE, THERMAL MAGNETIC; BQ FRAME; 240 VAC AT 60 HZ; 100 AMPERE; 3 POLE; TERMINAL NOT INCLUDED; FXD6 MODEL _
|
Siemens
|
BQ3B080C
|
CIRCUIT BREAKER, THERMAL MAGNETIC, MOLDED CASE; BQ FRAME; 240 VAC AT 50/60 HZ (UL); 80 AMPERE AT 40 DEG C; 3 POLE; INTERRUPTING RATING 10000 AMPERE; TERMINAL RING; SIZE 3 INCH W X 3 INCH D X 4 INCH H; APPROVAL UL 489, UL 1066, CE _
|