CED6

Артикул Наименование Производитель
CED63A040 ELECTRONIC; 600 VAC AT 50/60 HZ, 250 VDC; 40 AMPERE; 3 POLE; TRIP SETTING 115 TO 375 AMPERE; MOTOR FLA 8.84 TO 34 AMPERE; TERMINAL NOT INCLUDED; SIZE 3 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 489, CSA C22.2; CED6 MODEL _ Siemens
CED63A002 MOLDED CASE CIRCUIT BREAKER, ELECTRONIC; 600 VAC AT 50/60 HZ, 250 VDC; 2 AMPERE; 3 POLE; TRIP SETTING 7 TO 22 AMPERE; MOTOR FLA 0.53 TO 2 AMPERE; TERMINAL NOT INCLUDED; SIZE 3 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 489, CSA C22.2; CED6 MODEL _ Siemens
CED63B110L THERMAL MAGNETIC; 3 POLE; 600 VAC; 110 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC; LINE LUG, LOAD LUG TERMINAL _ Siemens
CED63S125A MOLDED CASE SWITCH, CED6 FRAME; 240/480/600 VAC AT 50/60 HZ, 500 VDC (UL); 220/240/380/415 VAC AT 50/60 HZ (IEC); 125 AMPERE AT 40 DEG C; 3 POLE; SIZE 3 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 1087, CSA C22.2; SPEEDFAX[T] BRAND _ Siemens
CED63A030 ELECTRONIC; 600 VAC AT 50/60 HZ, 250 VDC; 30 AMPERE; 3 POLE; TRIP SETTING 80 TO 270 AMPERE; MOTOR FLA 6.15 TO 24.5 AMPERE; TERMINAL NOT INCLUDED; SIZE 3 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 489, CSA C22.2; CED6 MODEL _ Siemens
CED63S100A MOLDED CASE SWITCH, CED6 FRAME; 240/480/600 VAC AT 50/60 HZ, 500 VDC (UL); 220/240/380/415 VAC AT 50/60 HZ (IEC); 100 AMPERE AT 40 DEG C; 3 POLE; SIZE 3 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 1087, CSA C22.2; SPEEDFAX[T] BRAND _ Siemens
CED63A005 MOLDED CASE CIRCUIT BREAKER, ELECTRONIC; 600 VAC AT 50/60 HZ, 250 VDC; 5 AMPERE; 3 POLE; TRIP SETTING 16 TO 54 AMPERE; MOTOR FLA 1.23 TO 4.9 AMPERE; TERMINAL NOT INCLUDED; SIZE 3 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 489, CSA C22.2; CED6 MODEL _ Siemens
CED63B015L FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 15 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC (UL); LUG TERMINAL _ Siemens
CED63A030 ELECTRONIC; 600 VAC AT 50/60 HZ, 250 VDC; 30 AMPERE; 3 POLE; TRIP SETTING 80 TO 270 AMPERE; MOTOR FLA 6.15 TO 24.5 AMPERE; TERMINAL NOT INCLUDED; SIZE 3 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 489, CSA C22.2; CED6 MODEL _ Siemens
CED63M090 THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
CED63B070 FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL _ Siemens
CED63M125 THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC; LUG LOAD TERMINAL TERMINAL _ Siemens
CED63B125L FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 125 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC (UL); LUG TERMINAL _ Siemens
CED62B060L FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG TERMINAL _ Siemens
CED63M070 THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
CED62B060 FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 60 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG LOAD TERMINAL TERMINAL _ Siemens
CED63M020 THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 20 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC; LUG LOAD TERMINAL TERMINAL _ Siemens
CED62M090 THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
CED62M050 THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
CED6N3R CIRCUIT BREAKER ENCLOSURE, BREAKER; 1, 2, 3 POLE ED BREAKER; BREAKER/SWITCH CURRENT RATING 110 TO 125 AMPERE; NEMA 3R; SIZE 7-1/4 INCH W X 5-1/4 INCH D X 22-21/64 INCH H; SPEEDFAX[T] BRAND; CED MODEL _ Siemens
CED62B040L FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG TERMINAL _ Siemens
CED63B090L THERMAL MAGNETIC; 3 POLE; 600 VAC; 90 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC; LINE LUG, LOAD LUG TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER, LINE) _ Siemens
CED62B040 FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 40 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG LOAD TERMINAL TERMINAL _ Siemens
CED62S125A MOLDED CASE SWITCH, CED6 FRAME; 240/480/600 VAC AT 50/60 HZ, 250 VDC (UL); 220/240/380/415 VAC AT 50/60 HZ (IEC); 125 AMPERE AT 40 DEG C; 2 POLE; SIZE 2 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 1087, CSA C22.2; SPEEDFAX[T] BRAND _ Siemens
CED63M100 THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 100 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
CED63B050 FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 3 POLE; 600 VAC, 500 VDC; 50 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 50 KILOAMPERE AT 500 VDC (UL); LUG LOAD TERMINAL TERMINAL _ Siemens
CED62B070L FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 70 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG TERMINAL _ Siemens
CED62B030 FUSELESS CURRENT LIMITING, THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 30 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC (UL); LUG LOAD TERMINAL TERMINAL _ Siemens
CED62M080 THERMAL MAGNETIC; 2 POLE; 600 VAC, 250 VDC; 80 AMPERE AT 40 DEG C; INTERRUPTING RATING 200 KILOAMPERE AT 240/480 VAC, 100 KILOAMPERE AT 600 VAC, 30 KILOAMPERE AT 250 VDC; LUG LOAD TERMINAL TERMINAL; WIRE SIZE 10 TO 1/0 AWG (ALUMINUM/COPPER) _ Siemens
CED63A001 MOLDED CASE CIRCUIT BREAKER, ELECTRONIC; 600 VAC AT 50/60 HZ, 250 VDC; 1 AMPERE; 3 POLE; TRIP SETTING 2.6 TO 9 AMPERE; MOTOR FLA 0.2 TO 0.81 AMPERE; TERMINAL NOT INCLUDED; SIZE 3 INCH W X 4 INCH D X 9.26 INCH H; APPROVAL UL 489, CSA C22.2; CED6 MODEL _ Siemens