Артикул |
Наименование |
Производитель |
2GA5501-0A
|
KIT PHOTVOLTAIK LAB BENCH AND STANDBY POWER SUPPLY CONSISTING OF: PERFORATED MOUNTING, EXPERIMENTAL BOXES, SOLAR BATTERY, INVERTER, SOLAR MODULE WITH TUNGSTEN- HALOGEN REFLECTOR LAMP AND SET OF SOLAR INSTRUMENT LEADS (2GA55 01-1A TO 2GA55 01-1W AND 2GA55 01-2A)
|
Siemens
|
2GA5501-0B
|
PHOTOVOLTAIC TEACHING SYSTEM ON 297 X 493MM PANEL DIRECT VOLTAGE GENERATION AND STORAGE IN BATTERY DIVIDED INTO 8 STEPS PHOTOVOLTAIC GENERATOR OVERVOLTAGE PROTECTOR DISCHARGE PROTECTOR CHARGE PROTECTOR EXHAUSTIVE DISCHARGE PROTECTOR BATTERY COMPARTMENT LOAD FUSE LOAD(2 MOTOR-CAR STAND.SOCKETS) BATTERY: 12V , 1.3 AH SOLAR MODULE: 200 MA ON 297 X 226MM PANEL WITH BASE
|
Siemens
|
2GA5501-1L
|
GENERAL LIGHTING WITH 230 V/40 W LAMP WITH E 14 BASE
|
Siemens
|
2GA5501-1K
|
START RELAY FOR CIRCUITS WITH 12 V LOADS
|
Siemens
|
2GA5501-1D
|
DISCHARGE PROTECTOR WITH 45 V/5 A LOW-LOSS SCHOTTKY DIODE WITH 0,3 V TRESHOLD VOLTAGE
|
Siemens
|
2GA5501-1S
|
INVERTER 12/220 V, 220 VA/50 HZ INCL. BUILT-IN CHARGER AND ANALOG INSTRUMENTS FOR 220 V AC AND 0 TO 2A AC
|
Siemens
|
2GA5501-1A
|
PHOTOVOLTAIC GENERATOR WITH CONNECTING LEAD 30 CM AND PLUG FOR CONNECTING TO SOLAR MODULE GENERATOR DATA 14,6 V / 1,5 A
|
Siemens
|
2GA5501-1M
|
LOAD MCB 16 A, B-TYPE MCB
|
Siemens
|
2GA5501-1B
|
SOLAR BATTERY 12 V/50 AH TABLE-TOP
|
Siemens
|
2GA5501-1N
|
DISTRIBUTION FUSE FOR PROTECTING LOADS AGAINST OVERLOAD AND SHORT-CIRCUIT, 25 A, B-TYPE MCB
|
Siemens
|
2GA5501-1C
|
OVERVOLTAGE PROTECTOR WITH THREE VDR RESISTORS AS AN EXEMPLE FOR INTERNAL LIGHTNING PROTECTION (APPLIANCE PROTECTION)
|
Siemens
|
2GA5501-1R
|
12 V ENERGY-SAVING LAMP FOR EXTERNAL CONNECTION
|
Siemens
|
2GA5501-1V
|
CONTACTOR RELAY WITH 3 NO+1 NC CONTACT START CONTACTOR FOR INVERTER OR OTHER SWITCHING OPERATIONS, DRIVEN BY PHASE-FAILURE RELAY
|
Siemens
|
2GA5501-1H
|
EMERGENCY LIGHTING (NON-MAINTAINED) WITH EXCAPE ROUTE SYMBOL TO DIN STANDARDS AND 230 V/15 W LAMP WITH E 14 BASE
|
Siemens
|
2GA5501-1E
|
CHARGE PROTECTOR THREE-LED STATUS DISPLAY: CHARGING VOLTAGE TOO LOW BATTERY IS CHARGED AND CHARGE STOPS MAX. PERMISSIBLE REGULATOR CHARGING CURRENT: 5 A
|
Siemens
|
2GA5501-1T
|
SYSTEM SELECTOR CONTACTOR WITH THREE NO AND ONE NC CONTACT FOR SWITCHING FROM INVERTER OPERATION TO SYSTEM OPERATION AND VICE VERSA
|
Siemens
|
2GA5501-1F
|
FLAT-BATTERY PROTECTOR FOR PROTECTING THE BATTERY WHEN THE VOLTAGE DROPS BELOW 10,8 V
|
Siemens
|
2GA5501-1U
|
PHASE-FAILURE RELAY PICKS UP ON FAILURE OF ONE OR MORE PHASES. IN SINGLE-PHASE OPERATION, L1, L2 AND L3 ARE JUMPERED (THREE PHASE SIMULATION)
|
Siemens
|
2GA5501-1G
|
CONSUMER 12V 3 X MOTOR-CAR STANDARD SOCKETS FOR 12V LOAD
|
Siemens
|
2GA5501-2A
|
SOLAR MODULE WITH 230 V/500 W TUNGSTEN- HALOGEN REFLECTOR LAMP AND MECHANISM FOR MODIFYING THE ANGLE OF INCIDENCE (AZIMUTH AND ELEVATION) FOR INVESTIGATING GENERATOR CHARACTERISTICS UNDER VARIOUS CONDITIONS
|
Siemens
|
2GA5502-2E
|
SOLAR CHARGING REGULATOR WITH FLAT-BATTERY PROTECTOR AND DIGITAL DISPLAY FOR CHARGING AND DISCHARGE CURRENT, AND FOR THE BATTERY VOLTAGE
|
Siemens
|
2GA5501-1W
|
SET OF SOLAR INSTRUMENT LEADS SAFETY LEADS CONSISTING OF 10 LEADS 10 CM RED 10 LEADS 10 CM BLUE 4 LEADS 25 CM RED 4 LEADS 25 CM BLUE 6 LEADS 25 CM BLACK 4 LEADS 50 CM RED 4 LEADS 50 CM BLUE 4 LEADS 100 CM RED 4 LEADS 100 CM BLUE 2 LEADS 100 CM BLACK 2 ADAPTERS FOR INVERTER 1 CORD FOR NON-HEATING
|
Siemens
|
2GA5501-1J
|
EMERGENCY LIGHTING (MAINTAINED) WITH 12 V/2 W TUBULAR FILAMENT LAMP AND EXCAPE ROUTE SYMBOL TO DIN STANDARDS
|
Siemens
|
2GA5502-2F
|
BATTERY CONTROLLER WITH LCD DISPLAY FOR BATTERY VOLTAGE, CHARGING AND DISCHARGE CURRENTS, CHARGE/DISCHARGE STATE, INCL. 60 A MEASURING SHUNT
|
Siemens
|