6ES7 671-0RC07-0YA0

Product type designation

SIMATIC WinAC RTX 2009

Product version

 

Hardware product version

-

Firmware version

4.5

associated programming package

STEP7 V5.4 SP4 or higher + HW update / iMap V3.0 SP1

Memory

 

Work memory

 

  • integrated (for program)

4 Mbyte; Adjustable; depends on Non Paged Memory Pool

  • integrated (for data)

4 Mbyte; Adjustable; depends on Non Paged Memory Pool

Load memory

 

  • integrated RAM, max.

Adjustable; depends on Non Paged Memory Pool

CPU/ blocks

 

DB

 

  • Number, max.

65 535; Limited only by RAM set for data

  • Size, max.

64 Kibyte

FB

 

  • Number, max.

65 536; Limited only by RAM set for code

  • Size, max.

64 Kibyte

FC

 

  • Number, max.

65 536; Limited only by RAM set for code

  • Size, max.

64 Kibyte

OB

 

  • Number, max.

Limited only by RAM set for code

  • Size, max.

64 Kibyte

  • Number of free cycle OBs

1; OB 1

  • Number of time alarm OBs

1; OB 10

  • Number of delay alarm OBs

1; OB 20

  • Number of time alarm OBs

9; OB 30-38

  • Number of process alarm OBs

1; OB 40

  • Number of ODK OBs

3; OB 52-54

  • Number of DPV1 alarm OBs

3; OB 55-57

  • Number isochronous mode OBs

2; OB 61-62

  • Number of startup OBs

2; OB 100, 102

  • Number of asynchronous error OBs

7; OB 80, 82-85, 86, 88

  • Number of synchronous error OBs

2; OB 121, 122

Nesting depth

 

  • per priority class

24

  • additional within an error OB

24

CPU processing times

 

for bit operations, min.

0.004 µs; typ.

for fixed point arithmetic, min.

0.003 µs; typ.

for floating point arithmetic, min.

0.004 µs; typ.

Reference platform

Pentium IV, 2.4 GHz

Counters, timers and their retentivity

 

S7 counter

 

  • Number

2 048

  • Retentivity

 

    • can be set

Yes

    • lower limit

0

    • upper limit

2 047

    • preset

8

  • Counting range

 

    • can be set

Yes

    • lower limit

0

    • upper limit

999

IEC counter

 

  • present

Yes

  • Type

SFB

S7 times

 

  • Number

2 048

  • Retentivity

 

    • can be set

Yes

    • lower limit

0

    • upper limit

2 047

    • preset

0

  • Time range

 

    • lower limit

10 ms

    • upper limit

9 990 s

IEC timer

 

  • present

Yes

  • Type

SFB

Data areas and their retentivity

 

Retentivity without UPS and PS Extension Board

128 KB with SIMATIC IPC427C and HMI IPC477C; further SIMATIC PCs on request

Retentivity with UPS

all data

Flag

 

  • Number, max.

16 Kibyte

  • of which retentive

MB 0 to MB 16383

  • Retentivity preset

MB 0 to MB 15

  • Number of clock memories

8

Local data

 

  • adjustable, max.

32 Kibyte

  • preset

16 Kibyte

  • per priority class, max.

32 Kibyte

Address area

 

I/O address area

 

  • overall

16 Kibyte

  • Outputs

16 Kibyte

  • of which, distributed

 

    • DP interface, inputs

16 Kibyte

    • DP interface, outputs

16 Kibyte

    • PN interface, inputs

16 Kibyte

    • PN interface, outputs

16 Kibyte

Process image

 

  • Inputs, adjustable

8 Kibyte

  • Outputs, adjustable

8 Kibyte

  • Inputs, default

512 byte

  • Outputs, default

512 byte

Subprocess images

 

  • Number of subprocess images, max.

15

Digital channels

 

  • Inputs

128 000

  • Outputs

128 000

Analog channels

 

  • Inputs

8 000

  • Outputs

8 000

Hardware configuration

 

Submodules

 

  • Number of submodules, max

4

  • of which PROFIBUS, max.

4; Supported interfaces: see 1st and 2nd interface

  • of which Industrial Ethernet, max.

1; Supported interfaces: see 3rd and 4th interface

Number of operable FMs and CPs (recommended)

 

  • FM

FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2

  • CP, point-to-point

2; CP 340, CP 341 distributed

  • CP, LAN

Over PC CP

Time of day

 

Clock

 

  • Hardware clock (real-time clock)

Yes

  • battery-backed and synchronizable

Yes

Runtime meter

 

  • Number

8

Clock synchronization

 

  • supported

Yes

  • to PC-CP, slave

Yes

  • on Ethernet via NTP

Yes

S7 message functions

 

Number of login stations for message functions, max.

62

SCAN procedure

No

Process diagnostic messages

Yes; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQ

simultaneously active Alarm-S blocks, max.

20; of a total of 20 for all SFCs

Alarm 8-blocks

Yes

  • Number of instances for alarm 8 and S7 communication blocks, max.

600

Process control messages

No

Test commissioning functions

 

Status/control

 

  • Status/control variable

Yes

Forcing

 

  • Forcing

No

Status block

Yes

Single step

Yes

Diagnostic buffer

 

  • present

Yes

  • Number of entries, max.

3 200

    • preset

120

Communication functions

 

PG/OP communication

Yes

Data record routing

No

Global data communication

 

  • supported

No

S7 basic communication

 

  • supported

No

S7 communication

 

  • supported

Yes

  • as server

Yes

  • as client

Yes

  • User data per job, max.

64 Kibyte; Depends on which block is used: BSEND/USEND or PUT/GET

Web server

 

  • supported

No

Open IE communication

 

  • TCP/IP

Yes

    • Number of connections, max.

Dependent on interface

    • Data length, max.

65 534 byte

  • ISO-on-TCP (RFC1006)

No

  • UDP

Yes

    • Number of connections, max.

Dependent on interface

    • Data length, max.

1 472 byte

Number of connections

 

  • overall

64

  • usable for PG communication

 

    • reserved for PG communication

1

  • usable for OP communication

 

    • reserved for OP communication

1

PROFINET CBA (at set setpoint communication load)

 

  • Setpoint for the CPU communication load

20 %

  • Number of remote interconnection partners

64

  • Number of functions, master/slave

30

  • Total of all Master/Slave connections

1 000

  • Data length of all incoming connections master/slave, max.

6 800 byte

  • Data length of all outgoing connections master/slave, max.

6 800 byte

  • Number of device-internal and PROFIBUS interconnections

500

  • Data length of device-internal und PROFIBUS interconnections, max.

4 000 byte

  • Data length per connection, max.

1 400 byte

  • Remote interconnections with acyclic transmission

 

    • Sampling frequency: Sampling time, min.

500 ms

    • Number of incoming interconnections

100

    • Number of outgoing interconnections

100

    • Data length of all incoming interconnections, max.

2 000 byte

    • Data length of all outgoing interconnections, max.

2 000 byte

    • Data length per connection, max.

1 400 byte

  • Remote interconnections with cyclic transmission

 

    • Transmission frequency: Transmission interval, min.

10 ms

    • Number of incoming interconnections

200

    • Number of outgoing interconnections

200

    • Data length of all incoming interconnections, max.

4 800 byte

    • Data length of all outgoing interconnections, max.

4 800 byte

    • Data length per connection, max.

250 byte

  • HMI variables via PROFINET (acyclic)

 

    • Number of stations that can log on for HMI variables (PN OPC/iMap)

3

    • HMI variable updating

500 ms

    • Number of HMI variables

200

    • Data length of all HMI variables, max.

2 000 byte

  • PROFIBUS proxy functionality

 

    • supported

Yes

    • Number of linked PROFIBUS devices

16

    • Data length per connection, max.

240 byte; Slave-dependent

1st interface

 

Type of interface

CP 5611-A2, CP 5621, integrated PB interface of the SIMATIC PC

Max. no. of simultaneously operable CPs

1

Physics

RS 485 / PROFIBUS

Isolated

Yes

Power supply to interface (15 to 30 V DC), max.

does not exist

Functionality

 

  • MPI

No

  • DP master

Yes

  • DP slave

No

DP master

 

  • Number of connections, max.

8

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes

    • Equidistance mode support

Yes; Only in conjunction with isochronous mode

    • Isochronous mode

Yes

    • SYNC/FREEZE

Yes

    • Activation/deactivation of DP slaves

Yes

    • Direct data exchange (slave-to-slave communication)

Yes

    • DPV0

Yes

    • DPV1

Yes

  • Transmission rate, max.

12 Mbit/s

  • Number of DP slaves, max.

64

  • Address area

 

    • Inputs, max.

16 Kibyte

    • Outputs, max.

16 Kibyte

  • User data per DP slave

 

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

2nd interface

 

Type of interface

CP 5613, CP 5613-A2, CP 5603

Max. no. of simultaneously operable CPs

4

Physics

RS 485 / PROFIBUS

Isolated

Yes

Functionality

 

  • MPI

No

  • DP master

Yes

  • DP slave

No

DP master

 

  • Number of connections, max.

50

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes

    • Global data communication

No

    • S7 basic communication

No

    • S7 communication

Yes

    • Equidistance mode support

Yes; Only in conjunction with isochronous mode

    • Isochronous mode

Yes

    • SYNC/FREEZE

Yes

    • Activation/deactivation of DP slaves

Yes

    • Direct data exchange (slave-to-slave communication)

Yes

    • DPV0

Yes

    • DPV1

Yes

  • Transmission speeds, max.

12 Mbit/s

  • Number of DP slaves, max.

125

  • Address area

 

    • Inputs, max.

16 Kibyte

    • Outputs, max.

16 Kibyte

  • User data per DP slave

 

    • Inputs, max.

244 byte

    • Outputs, max.

244 byte

3rd interface

 

Type of interface

PROFINET

Max. no. of simultaneously operable CPs

1; Intel Pro/1000 (Intel 82571EB, 82573L, 82574L, 82541PI; non shared IRQ required); integrated IE interface SIMATIC PC 4x7B, 6x7B, 8x7B and IPC4x7C

Physics

Ethernet

Isolated

Yes

automatic detection of transmission speed

Yes; 10/100 Mbit/s

Functionality

 

  • PROFINET IO Controller

Yes

  • PROFINET IO Device

No

  • PROFINET CBA

Yes

  • Open IE communication

Yes

  • Web server

No

PROFINET IO Controller

 

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes; S7 routing

    • S7 communication

Yes

    • Open IE communication

Yes

  • Transmission rate, min.

100 Mbit/s

  • Transmission rate, max.

100 Mbit/s

  • Number of connectable IO Devices, max.

128

  • IRT, supported

No

  • Prioritized startup supported

Yes

    • Number of IO Devices, max.

32

  • Activation/deactivation of IO Devices

Yes

    • Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • IO Devices changing during operation (partner ports), supported

Yes

  • Device replacement without swap medium

Yes

  • Send clock times

1 ms

  • Updating time

1 - 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data)

  • Address area

 

    • Inputs, max.

16 Kibyte

    • Outputs, max.

16 Kibyte

  • User data per address area, max.

2 kbyte

    • User data consistency, max.

256 byte

SIMATIC communication

 

  • PG/OP communication

Yes

  • S7 routing

Yes

  • S7 communication

Yes

  • Number of connections, max.

16

Open IE communication

 

  • Open IE communication, supported

Yes

  • Number of connections, max.

32

  • Local port numbers used at the system end

0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535

4th interface

 

Type of interface

PROFINET

Max. no. of simultaneously operable CPs

1; CP 1616 (HW release 8 or above), CP 1604 (HW release 7 or higher), integrated PN interface of SIMATIC PC and S7-mEC

Physics

Ethernet

Isolated

Yes

automatic detection of transmission speed

Yes; 10/100 Mbit/s

Functionality

 

  • PROFINET IO Controller

Yes

  • PROFINET CBA

Yes

  • Open IE communication

Yes

  • Web server

No

PROFINET IO Controller

 

  • Services

 

    • PG/OP communication

Yes

    • Routing

Yes; S7 routing

    • S7 communication

Yes

    • Open IE communication

Yes

  • Transmission rate, min.

100 Mbit/s

  • Transmission rate, max.

100 Mbit/s

  • Number of connectable IO devices, max.

256

  • Number of IO Devices with IRT and the option "high flexibility", max.

64

    • of which in line, max.

32

  • IRT, supported

Yes

  • Prioritized startup supported

Yes

    • Number of IO Devices, max.

32

  • Activation/deactivation of IO Devices

Yes

    • Number of IO Devices that can be simultaneously activated/deactivated, max.

8

  • IO Devices changing during operation (partner ports), supported

Yes

  • Device replacement without swap medium

Yes

  • Send clock times

250 µs, 500 µs, 1 ms

  • Updating time

0.25...512 depending on the send cycle

  • Address area

 

    • Inputs, max.

16 Kibyte

    • Outputs, max.

16 Kibyte

  • User data per address area, max.

2 kbyte

    • User data consistency, max.

256 byte

SIMATIC communication

 

  • PG/OP communication

Yes

  • S7 routing

Yes

  • S7 communication

Yes

  • Number of connections, max.

32

Open IE communication

 

  • Open IE communication, supported

Yes

  • Number of connections, max.

32

  • Local port numbers used at the system end

0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535

Isochronous mode

 

Isochronous mode

Yes; only PROFIBUS

Number of DP masters with isochronous mode

2

User data per isochronous slave, max.

128 byte

equidistance

Yes

shortest clock pulse

2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image

CPU/ programming

 

Programming language

 

  • STEP 7

Yes; V5.4, SP4 or higher, Engineering Tools (optional)

  • LAD

Yes

  • FBD

Yes

  • STL

Yes

  • SCL

Yes

  • CFC

Yes

  • GRAPH

Yes

  • HiGraph®

Yes

Nesting levels

8

Know-how protection

 

  • User program protection/password protection

Yes

Software libraries

 

  • Easy Motion Control

Yes

Open Development interfaces

 

  • CCX (Custom Code Extension)

Yes; WinAC ODK V4.2 or higher

  • SMX (Shared Memory Extension)

Yes; WinAC ODK V4.2 or higher

    • Inputs

4 Kibyte

    • Outputs

4 Kibyte

  • CMI (Controller Management Interface)

Yes; WinAC ODK V4.2 or higher

Number of simultaneously active SFCs

 

  • DPSYC_FR

20; of a total of 20 for all SFCs

  • D_ACT_DP

20; of a total of 20 for all SFCs

  • RD_REC

20; of a total of 20 for all SFCs

  • WR_REC

20; of a total of 20 for all SFCs

  • WR_PARM

20; of a total of 20 for all SFCs

  • PARM_MOD

20; of a total of 20 for all SFCs

  • WR_DPARM

20; of a total of 20 for all SFCs

  • DPNRM_DG

20; of a total of 20 for all SFCs

  • RDSYSST

20; of a total of 20 for all SFCs

Number of simultaneously active SFBs

 

  • RD_REC

20; of a total of 20 for all SFBs

  • WR_REC

20; of a total of 20 for all SFBs

Hardware requirements

 

Hardware required

PC with color monitor, keyboard, mouse or pointing device for Windows

Required memory on hard disk, min.

100 Mbyte

Main memory, min.

1 Gbyte

Processor

Intel Celeron M, 900 MHz or compatible

  • Multi-processor system

Yes; Dual Pentium, CoreDuo, Core2Duo or compatible

  • Hyper-threading

Yes

Operating systems

 

Operating system

 

  • Windows NT 4.0

No

  • Windows 2000

No

  • Windows XP

Yes; Professional, SP2 and SP3

  • Windows XP embedded

Yes; With the delivery image of the SIMATIC PC

  • Windows Vista

No

Dimensions and weight

 

Weight

 

  • Weight, approx.

100 g; with packaging